SOPERTON, GA —
OSHA Inspection: MODUTEK INTERNATIONAL, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MODUTEK INTERNATIONAL, LLC in 394 PARK VIEW DRIVE, SOPERTON, GA 30457 (NAICS 335312). OSHA activity number 348395971.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MODUTEK INTERNATIONAL, LLC
- Site address
- 394 PARK VIEW DRIVE
- City
- SOPERTON
- State
- GA
- ZIP
- 30457
- Mailing
- 394 PARK VIEW DRIVE, SOPERTON, GA 30457
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- Employees
- 126
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 B05 I
- Issued
- Aug 29, 2025
- Abate by
- Sep 25, 2025
- Penalty
- Initial $5,107 · Current $3,064 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained: (a) In the spray booth in the production area, on March 23, 2025, visible gauges, audible alarms, or pressure activated devices were not installed to indicate or ensure that the required air velocity was maintained, exposing employees to a fire and respiratory hazard.
Recent events (2)
- — I (S) $3064.2
- — Z (S) $5107
1910.107 B09
- Issued
- Aug 29, 2025
- Abate by
- Sep 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: (a) In the production area at the spray booth, on July 23, 2025, paints and other combustible materials were stored within 3 feet and adjacent to the spray booth, exposing employees to a fire hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Aug 29, 2025
- Abate by
- Sep 25, 2025
- Penalty
- Initial $5,107 · Current $3,064 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) In the production area at the spray booth, on or about July 23, 2025, the employer exposed an employee to respiratory hazards in that, the employer did not provide a medical evaluation before employees were fit tested or required to use respiratory protection.
Recent events (2)
- — I (S) $3064.2
- — Z (S) $5107
1910.134 F02
- Issued
- Aug 29, 2025
- Abate by
- Sep 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: (a) In the production area at the spray booth, on or about July 23, 2025, the employer exposed employees to respiratory hazards, in that the employer did not provide annual fit testing to an employee required to use respiratory protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Aug 29, 2025
- Abate by
- Sep 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) In the production area at the spray booth, on or about July 23, 2025, an employee who was required to wear a tight-fitting respirator was permitted to have facial hair that came between the sealing surface of the facepiece and the face, thereby exposing employees to respiratory hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.41 A01 I
- Issued
- Aug 29, 2025
- Abate by
- Sep 25, 2025
- Penalty
- Initial $1,702 · Current $1,021 Reduced
General-duty citation text
29 CFR 1904.41(a)(1)(i): The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date: (a) Modutek International LLC, Soperton, Georgia; On or about July 23, 2025, the employer failed to electronically submit information from their OSHA Form 300A, Summary of Work-Related Injuries and Illnesses or equivalent form, for calendar year 2024 on or before March 2, 2025. The establishment employed 119 employees during calendar year 2024 and was classified under NAICS code 335312.
Recent events (2)
- — I (O) $1021.2
- — Z (O) $1702
More inspections in this industry (NAICS 335312)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348395971.