Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GILBARTO RESENDIZ CHAVEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GILBARTO RESENDIZ CHAVEZ in LOT 20 KATEANE DRIVE, DAWSONVILLE, GA 30534 (NAICS 238130). OSHA activity number 348396797.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gilbarto Resendiz Chavez — free Get an email when a new federal OSHA severe-injury report for Gilbarto Resendiz Chavez is published. One employer, no account, unsubscribe in one click.
Site address
LOT 20 KATEANE DRIVE
City
DAWSONVILLE
State
GA
ZIP
30534
Mailing
285 W HIGHLAND STREET, BLUE RIDGE, GA 30513
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 20, 2025
Penalty
Initial $2,270 · Current $2,270
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:  a) New residential construction located at Lot 20 Kateane Drive, Dawsonville, GA 30534, Top plate: On or about 07/25/2025, the employer exposed employees to fall hazards of approximately 18-feet, to the lower level, in that a fall protection system was not provided to employees engaged in framing activities.
Recent events (1)
  • — Z (S) $2270

1926.403 B01

Other-than-serious 1 instance 3 exposed
Issued
Aug 20, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.403(b)(1):Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:  a) New residential construction located at Lot 20 Kateane Drive, Dawsonville, GA 30534: On or about 07/25/2025, the employer failed to inspect all electrical extension cords used to provide power to electric tools, in that a 50 ft red and black electrical cord was damaged and exposing the internal insulated energized wires. An inspection of these cords was not performed prior to the shift as these cords were not repaired or removed from service.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348396797.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.