LINCOLN, NE —
OSHA Inspection: PACAM LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PACAM LLC in 6616 GRAY'S PEAK CT., LINCOLN, NE 68516 (NAICS 238220). OSHA activity number 348398454.
Where did this inspection happen?
- Establishment
- PACAM LLC
- Site address
- 6616 GRAY'S PEAK CT.
- City
- LINCOLN
- State
- NE
- ZIP
- 68516
- Mailing
- 8333 EIGER DRIVE, LINCOLN, NE 68516
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 77
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $9268.00 · Current $9268.00
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). On or about July 24, 2025, employees of Patriot Plumbing Heating and Air Conditioning were engaged in excavation activities at a jobsite located at 6616 Gray's Peak Court, Lincoln, NE 68516, and were exposed to cave-in hazards in that they were working in an unprotected trench that was in excess of 5-feet deep without any cave-in protections. This failure was most evident in the collapse of the trench in which an employee was caught within and injured.
Recent events (1)
- — Z (S) $9268
1904.40 A
- Issued
- Abate by
- Penalty
- Initial $1324.00 · Current $1324.00
General-duty citation text
29 CFR 1904.40(a):The employer did not provide an authorized government representative the records within the four business hours. Patriot Plumbing Heating and Air Conditioning failed to provide their OSHA 300 Logs and Form 300A for their facility located at 8333 Eiger Drive Lincoln, NE 68516 to an authorized OSHA representative within four hours of the representative making both an oral informal and a formal written request for said documents. Instances of failure to respond include but are not limited to: i. On or about July 24, 2024, when OSHA made a verbal request to the company during the opening conference and site walkaround. ii. On or about July 25, 2024, when OSHA made a written request to the company via email, quoting this requirement from the 1904.40(a). iii. On or about July 28, 2024, when OSHA made a verbal request to the company during a visit to the company headquarters while conducting interviews. ii. On or about July 28, 2024, when OSHA made a written request to the company via email, quoting this requirement from the 1904.40(a).
Recent events (1)
- — Z (O) $1324
More inspections in this industry (NAICS 238220)
LOS ANGELES, CA—2026-07-10
PRIME SC MECHANICAL INC.
RICHARDSVILLE, KY—2026-07-10
69312 - SIEGRIST SERVICE COMPANY LLC
PONCE, PR—2026-07-10
WILLIAM ECHEVARR�A ANDINO
MODESTO, CA—2026-07-09
R.L. FULLER, INC.
SAN JOSE, CA—2026-07-09
ROOTER HERO
More inspections in NE
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
BLAIR, NE—2026-06-30
NATUREWORKS LLC
EDISON, NE—2026-06-30
AG VALLEY COOP
Source