BROOMFIELD, CO —
OSHA Inspection: MAP CONSTRUCTIONS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAP CONSTRUCTIONS LLC in 11343 AND 11341 UPTOWN AVE, BROOMFIELD, CO 80021 (NAICS 238170). OSHA activity number 348405879.
Where did this inspection happen?
- Establishment
- MAP CONSTRUCTIONS LLC
- Site address
- 11343 AND 11341 UPTOWN AVE
- City
- BROOMFIELD
- State
- CO
- ZIP
- 80021
- Mailing
- 406 PINYON STREET, FREDERICK, CO 80530
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $3972.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. b) 11341 Colony Cir, Broomfield, CO 80021: On or about July 28, 2025, and at times prior, an employee performing siding operations and building a pump jack scaffold was exposed to fall hazards greater than 6 feet while accessing the scaffold by climbing onto it from a balcony railing of the second level. The employer failed to ensure employees were provided a safe means of access to reach the scaffold during assembly and work.
Recent events (2)
- — I (S) $2000
- — Z (S) $3972
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) On or about July 28, 2025, employees were exposed to fall hazards while working from a pump jack scaffold in that poles were not secured to the structure at intermediate points along the pole as necessary. Poles in excess of 30 ft in length were in use with only the top brace in use. The scaffold poles and platform moved excessively during use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. a) On or about July 28, 2025, employees erecting pump jack scaffolding at the jobsite were not providing with training on proper assembly, access and hazards associated with working from an elevated scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Penalty
- Initial $3972.00 · Current $2392.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 11345 Colony Cir, Broomfield, CO 80021: On or about July 28, 2025, and at times prior, an employee performing siding operations was exposed to fall hazards greater than 6 feet while working on the second level of a two-story residential building roof. The employer failed to ensure employees were protected from falls by utilizing a fall protection system or guardrails. b) 11341 Colony Cir, Broomfield, CO 80021: On or about July 28, 2025, and at times prior, an employee performing siding operations and building a pump jack scaffold was exposed to fall hazards greater than 6 feet while standing on the balcony railing of the second level patio. The employer failed to ensure employees were protected from falls by utilizing a fall protection system or guardrails.
Recent events (2)
- — I (S) $2392
- — Z (S) $3972
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2838.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about July 28, 2025, employees were exposed to falls in excess of 20 ft while using an extension ladder to access a second-story roof that did not extend at least 3 ft above the roof surface.
Recent events (2)
- — I (S) $1000
- — Z (S) $2838
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348405879.