ALMA, GA —
OSHA Inspection: RENEWABLE ENERGY & ANIMAL PROTEINS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RENEWABLE ENERGY & ANIMAL PROTEINS, LLC in 1255 US HIGHWAY 1 SOUTH, ALMA, GA 31510 (NAICS 311613). OSHA activity number 348406307.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RENEWABLE ENERGY & ANIMAL PROTEINS, LLC
- Site address
- 1255 US HIGHWAY 1 SOUTH
- City
- ALMA
- State
- GA
- ZIP
- 31510
- Mailing
- 1255 US HIGHWAY 1 SOUTH, ALMA, GA 31510
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311613
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.28 B03 II
- Issued
- Dec 15, 2025
- Penalty
- Initial $4,341 · Current $2,605 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(ii):29 CFR 1910.28(b)(3)(ii): The employer did not ensure that each employee be protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems. A) By loading dock doors: On or about 7/30/2025, the employer exposed employees to a fall hazard in that a concrete drainage ditch was not covered to prevent employees from stepping into or tripping in the hole.
Recent events (2)
- — I (S) $2604.6
- — Z (S) $4341
1910.28 B11 II
- Issued
- Dec 15, 2025
- Penalty
- Initial $5,788 · Current $3,473 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements. A) By Press platform area: On or about 7/30/2025, the employer exposed employees to a fall hazard in that the two sets of stairs leading up to the Press Platform did not have a stair rail system on the open side(s).
Recent events (2)
- — I (S) $3472.8
- — Z (S) $5788
1910.305 B02 I
- Issued
- Dec 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: A) In the office by the restrooms: On or about 7/30/2025, the employer exposed employees to an electrical hazard in that each receptacle in the office by the restrooms did not have a faceplate.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Renewable Energy & Animal Proteins, LLC
View Renewable Energy & Animal Proteins, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311613)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348406307.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.