Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUCKET ENTERPRISES LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BUCKET ENTERPRISES LLC. in 4702 STATE ROUTE 55, SWAN LAKE, NY 12783 (NAICS 238190). OSHA activity number 348411257.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bucket Enterprises LLC. — free Get an email when a new federal OSHA severe-injury report for Bucket Enterprises LLC. is published. One employer, no account, unsubscribe in one click.
Site address
4702 STATE ROUTE 55
City
SWAN LAKE
State
NY
ZIP
12783
Mailing
PO BOX 401, WASHINGTONVILLE, NY 10992
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238190
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 28, 2026
Abate by
Feb 9, 2026
Penalty
Initial $11,585 · Current $11,585
29 CFR  1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a) Worksite - On or about July 30, 2025, employees were connecting sewer lines in an excavation that was approximately 28 feet deep and approximately 130 feet in length. The employees did not have a safe means of egress as the only exit was at the end of the excavtion uphill through a backfill pile of dirt and rough terrain.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.651 J01

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 28, 2026
Abate by
Feb 9, 2026
Penalty
Initial $11,585 · Current $11,585
29 CFR  1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face:  a) Worksite - On or about July 30, 2025, employees were tying in sewer lines in an excavation that was approximately 28 feet deep. The employees were not protected by the overhanging loose soil conditions that could fall of them and cause serious injuries.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.651 K01

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 28, 2026
Abate by
Feb 9, 2026
Penalty
Initial $11,585 · Current $11,585
29 CFR  1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:  a) Worksite - On or about July 30, 2025, employees were tying in sewer lines in an excavation that was approximately 28 feet deep and approximately 130 feet in length. The employer did not perform daily inspections of the excavation by a competent person to identify hazardous conditions.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.652 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 28, 2026
Abate by
Feb 9, 2026
Penalty
Initial $11,585 · Current $11,585
29 CFR  1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  a) Worksite - On or about July 30, 2025, employees were tying in sewer lines in an excavation trench that was approximately 28 feet deep and approximately 130 feet in length. The employer did not protect the employees working in the excavation trench from cave-ins by a protective system designed to do so.
Recent events (2)
  • — C (S) $11585
  • — Z (S) $11585

1926.652 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 28, 2026
Abate by
Feb 9, 2026
Penalty
Initial $11,585 · Current $11,585
29 CFR  1926.652(c)(4)(i): Support system used in an excavation over 20 feet deep which exceeded the requirements listed in the table in Appendix C; tabulated data used for protective system was not approved by a registered professional engineer:  a) Worksite - On or about July 30, 2025, employees were tying in sewer lines in an excavation trench that was approximately 28 feet deep and approximately 130 feet in length. The employer did not have a protective system in place that was approved by a registered professional engineer.