WINDER, GA —
OSHA Inspection: CRUZ GARCIA ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CRUZ GARCIA ROOFING in 170 ROXEYWOOD WAY, WINDER, GA 30680 (NAICS 238160). OSHA activity number 348411356.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRUZ GARCIA ROOFING
- Site address
- 170 ROXEYWOOD WAY
- City
- WINDER
- State
- GA
- ZIP
- 30680
- Mailing
- 2775 GRAY RD SE, SMYRNA, GA 30082
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Aug 11, 2025
- Penalty
- Initial $2,128 · Current $2,128
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a) New residential construction located in the Roxeywood Park Subdivision at 170 Roxeywood Way, Winder, GA 30680, Back Roof: On or about 07/31/2025, the employer exposed one employee to a struck-by hazard while operating pneumatic nail guns, in that protective eyewear was not provided to the employee installing roof shingles while operating these tools at 120 PSI.
Recent events (1)
- — Z (S) $2128
1926.501 B13
- Issued
- Aug 11, 2025
- Penalty
- Initial $2,837 · Current $2,837
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) New residential construction in the Roxeywood Park Subdivision at 170 Roxeywood Way, Winder, GA 30680, Back Roof: On or about 07/31/2025, the employer exposed employees to fall hazards while working on a 8/12 pitched roof with an eave height of approximately 20 feet, 8 inches to the lower ground level, in that a fall protection system was not provided while employees were engaged in roofing activities.
Recent events (1)
- — Z (S) $2837
More inspections in this industry (NAICS 238160)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348411356.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.