ORLANDO, FL —
OSHA Inspection: GATE GOURMET, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GATE GOURMET, INC. in 8401 CASA VERDE RD, ORLANDO, FL 32827 (NAICS 722320). OSHA activity number 348411505.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GATE GOURMET, INC.
- Site address
- 8401 CASA VERDE RD
- City
- ORLANDO
- State
- FL
- ZIP
- 32827
- Mailing
- 8401 CASA VERDE RD, ORLANDO, FL 32827
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722320
- Employees
- 206
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.303 G01
- Issued
- Dec 8, 2025
- Penalty
- Initial $7,093 · Current $2,123 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about July 30, 2025, at the dish room area: employees were exposed to electrical shock hazards of 110-220 volts, in that 5 electrical power disconnect boxes were blocked with carts, containers, a shower plastic tank, and other obstructions.
Recent events (2)
- — I (O) $2123.4
- — Z (S) $7093
1910.305 A02
- Issued
- Dec 8, 2025
- Penalty
- Initial $14,187 · Current $9,574 Reduced
General-duty citation text
29 CFR 1910.305(a)(2): Temporary electrical power and lighting installations of 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (a), (b) and (c) of this paragraph: a) On or about July 30, 2025, in the kitchen area: employees were exposed to electrical shock hazards of 110-120V in that, an extension cord was used as permanent electrical wiring to power a fan located inside of the cooler.
Recent events (2)
- — I (S) $9574.1
- — Z (S) $14187
1910.305 G01 IV C
- Issued
- Dec 8, 2025
- Penalty
- Initial $14,187 · Current $9,574 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, or similar openings. a) On or about July 30, 2025, in the kitchen area: employees were exposed to electrical shock hazards of 110-120V,in that, an extension cord was ran through the cooler door and up into the ceiling to power a fan.
Recent events (2)
- — I (S) $9574.1
- — Z (S) $14187
1910.138 A
- Issued
- Dec 8, 2025
- Abate by
- Jan 5, 2026
- Penalty
- Initial $70,935 · Current $63,850 Reduced
General-duty citation text
29 CFR 1910.138(a):The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. a) On or about July 30, 2025, in the kitchen area: employees were exposed to amputation hazards when using knifes to cut meat and vegetables without the use of cut-proof gloves. b) On or about July 30, 2025, in the kitchen area, employees were exposed to burn hazards while transferring hot cooked food to trays without the use of thermal protection gloves. The GATE GOURMET, INC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.138(a), which was contained in OSHA inspection number1658605, citation number 1, item number 1 and was affirmed as a final order on 10-04-2023, with respect to a workplace located at 165 Charles W Grant Pkwy Unit 301, Atlanta, GA 30354.
Recent events (2)
- — I (S) $63850
- — Z (R) $70935
1910.305 B02 I
- Issued
- Dec 8, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) On or about July 30, 2025, at the dish room area in the column next to the washing machine, employees were exposed to electrical hazards of 110-220 volts while washing kitchen utensils in that, the electrical outlet was missing a cover. b) On or about July 30, 2025, at the dish room area in the wall behind to the dish carts, employees were exposed to electrical shock hazards of 110-220 volts while washing the kitchen utensils, in that the electrical outlet was missing a cover.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Gate Gourmet, INC.
View Gate Gourmet, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 722320)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348411505.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.