Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MONTANOS CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MONTANOS CONSTRUCTION LLC in 182 ORIENT WAY, RUTHERFORD, NJ 07070 (NAICS 236118). OSHA activity number 348424060.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Montanos Construction LLC — free Get an email when a new federal OSHA severe-injury report for Montanos Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
182 ORIENT WAY
City
RUTHERFORD
State
NJ
ZIP
07070
Mailing
397 3RD AVE, NEWARK, NJ 07107
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 27, 2025
Penalty
Initial $4,256 · Current $4,256
29 CFR  1926.102(a)(1):The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    a) pump jack scaffold: Employees were installing and removing siding without utilizing eye protection exposing employees to eye injuries, on or about 8/7/25
Recent events (1)
  • — Z (S) $4256

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 27, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR 1926.416(a)(1): Employee(s) were permitted to work in proximity to electric power circuits that were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a) Pump jack scaffold right side: Employees were exposed to electrical hazard while working next to the weather head without any type of electrical PPE, on or about 8/7/25.
Recent events (1)
  • — Z (S) $4965

1926.451 B05 II

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 27, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform was able to support employees without tipping, or had guardrails which blocked employee access to the cantilevered end:  a) Pump jack scaffold: The end of a platform greater than 10 feet in length extended over it's support approximately 3 to 4 feet. The platform was not designed and installed so that the cantilevered portion of the platform was able to support employees without tipping, or had guardrails which blocked employee access to the cantilevered end exposing them to a 16 foot fall, on or about 8/7/25
Recent events (1)
  • — Z (S) $4965

1926.451 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 27, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used:   a) Pump Jack scaffold:  Employees were exposed to a 16 foot fall hazard while getting of the pump jack scaffold thru windows. The employer did not provide proper access, on or about 8/7/25.
Recent events (1)
  • — Z (S) $4965

1926.451 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 27, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   a) Pump jack scaffold: Employees were expose to a fall hazard of approximately 16 feet to the ground below while working from a pump jack scaffold without utilizing personal fall arrest system or any other means of fall protection, on or about 8/7/25.
Recent events (1)
  • — Z (S) $4965

1926.1053 B04

Serious Gravity 10 2 instances 4 exposed
Issued
Aug 27, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.  a)  Pump jack scaffold: Ladders were not used only for the purpose for which they were designed, on or about 8/7/25. -
Recent events (1)
  • — Z (S) $4965

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348424060.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.