GRAY, LA —
OSHA Inspection: OLYMPIAN MACHINE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OLYMPIAN MACHINE in 3655 WEST PARK AVENUE, GRAY, LA 70359 (NAICS 332996). OSHA activity number 348424508.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OLYMPIAN MACHINE
- Site address
- 3655 WEST PARK AVENUE
- City
- GRAY
- State
- LA
- ZIP
- 70359
- Mailing
- 3655 WEST PARK AVENUE, GRAY, LA 70359
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 27
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 C03 I
- Issued
- Jan 27, 2026
- Penalty
- Initial $4,965 · Current $2,979 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. a) On or about August 4, 2025, in the middle of the workshop, employees utilized custom-made circulation fans (blowers) whose motor wires were connected with wire nuts instead of properly insulated splices.
Recent events (2)
- — I (S) $2979
- — Z (S) $4965
1910.37 B02
- Issued
- Jan 27, 2026
- Abate by
- Feb 9, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) On or about August 4, 2025, on the left side of the workshop, employees worked near an emergency exit that was not marked with an "Exit" sign.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jan 27, 2026
- Abate by
- Feb 9, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) On or about August 4, 2025, in the middle of the workshop, employees utilized custom-made circulation fans (blowers) with a flexible power cord that had stress relief damage at the plug.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Olympian Machine