OSHA Inspection: SECURITY-LUEBKE ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SECURITY-LUEBKE ROOFING, INC. in 109 WALLACE STREET, COMBINED LOCKS, WI 54113 (NAICS 238160). OSHA activity number 348424789.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Security-Luebke Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Security-Luebke Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
109 WALLACE STREET
City
COMBINED LOCKS
State
WI
ZIP
54113
Mailing
3921 E ENDEAVOR DRIVE, APPLETON, WI 54915
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
96
Ownership type
A

3 citations on file for this inspection.

1926.502 D08

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Dec 10, 2025
Abate by
Jan 9, 2026
Penalty
Initial $13,902 · Current $6,951 Reduced
29 CFR  1926.502(d)(8):Horizontal lifelines shall be designed, installed, and used, under the supervision of a qualified person, as part of a complete personal fall arrest system, which maintains a safety factor of at least two.  On or about August 7, 2025, at an establishment located at 109 Wallace Street in Combined Locks, Wisconsin, employees of Security-Luebke Roofing, Inc. were performing residential roofing activities and were utilizing a designed horizonal lifeline with an incapable anchor point capable of supporting 5000lbs while exposed to fall hazards of over 17 feet 10 1/2 inches. There were two employees that were connected to a horizontal lifeline connected to anchors that were only designed for one employee.
Recent events (2)
  • — I (O) $6951
  • — Z (S) $13902

1926.502 D15

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Dec 10, 2025
Abate by
Jan 9, 2026
Penalty
Initial $13,902 · Current $0 Reduced
29 CFR  1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows:  On or about August 7, 2025, at an establishment located at 109 Wallace Street in Combined Locks, Wisconsin, employees of Security-Luebke Roofing, Inc. were performing residential roofing activities and were not utilizing a designed anchor point capable of supporting 5000lbs while exposed to fall hazards of over 17 feet 10 1/2 inches. There were two employees that were connected to a horizontal lifeline connected to anchors that were only designed for one employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13902

1926.501 B10

Deleted Repeat Gravity 10 1 instance 3 exposed
Issued
Dec 10, 2025
Abate by
Jan 9, 2026
Penalty
Initial $69,510 · Current $0 Reduced
29 CFR  1926.501(b)(10): Roofing work on Low-slope roofs.�Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.  On or about August 7, 2025, at a worksite located at 109 Wallace Street in Combined Locks, Wisconsin, employees were exposed to fall hazards of 17 feet 10 1/2 inches while conducting residential roofing activities on a low slope roof without the use of fall protection system.  Security-Luebke Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1628753, citation number 1, item number 1b and was affirmed as a final order on April 17, 2023, with respect to a workplace located at 4314 N Bull Rush Drive, Appleton, Wisconsin.  Security-Luebke Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1609109, citation number 1, item number 2 and was affirmed as a final order on September 28, 2022, with respect to a workplace located at 1570 N. Waterford Drive, Appleton Wisconsin.