Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCOMMODATIVE CONSTRUCTION SERVICES LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACCOMMODATIVE CONSTRUCTION SERVICES LLC in 11389 VERNON PLACE, MEADVILLE, PA 16335 (NAICS 236220). OSHA activity number 348427246.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accommodative Construction Services LLC — free Get an email when a new federal OSHA severe-injury report for Accommodative Construction Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
11389 VERNON PLACE
City
MEADVILLE
State
PA
ZIP
16335
Mailing
415 SHINGLISS ST., MC KEES ROCKS, PA 15136
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236220
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 26, 2025
Abate by
Oct 23, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   a.) Accommodative Construction Services LLC, 11389 Vernon Place, Meadville, PA 16335: On or about 08/06/2025 and at times prior thereto, Employees were exposed to fall hazards of approximately 20 feet to ground level while working off the 3rd buck of the frame scaffold at the front of the future shoe retail store. Employees were not protected by a complete guard rail system or a fall protection system.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (1)
  • — Z (S) $4965

1926.451 G04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 26, 2025
Abate by
Oct 23, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:  a.) Accommodative Construction Services LLC, 11389 Vernon Place, Meadville, PA 16335: On or about 08/08/2025 and at times prior thereto, Employees were exposed to fall hazards of approximately 15 feet to ground level while working off the 2nd buck of the frame scaffold at the front of the future shoe retail store without a complete guard rail. A mid-rail was not used below the cross bracing on the 2nd buck of the frame scaffold.   ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 26, 2025
Abate by
Oct 23, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is not fully planked.    a.) Accommodative Construction Services LLC, 11389 Vernon Place, Meadville, PA 16335: On or about 08/08/2025 and at times prior thereto, Employees were exposed to hazards associated with the working area of the 2nd buck of the frame scaffolding not being fully planked. Employees were exposed to fall hazards of 14 feet to ground level.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 H02

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 26, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR  1926.451(h)(2): Employees working below a scaffold were not protected from falling tools, materials or equipment in accordance with the provisions of paragraphs (h)(2)(i)-(v) of this section:   a.) Accommodative Construction Services LLC, 11389 Vernon Place, Meadville, PA 16335: On or about 08/08/2025 and at times prior thereto, Employees were exposed to overhead struck-by hazards while entering and exiting the building under the frame scaffolding. Employer did not utilize a toe board or barricade to prevent employees from walking under the scaffolding while employees were working above.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3547

1926.416 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 26, 2025
Abate by
Oct 23, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR  1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:     a.) Accommodative Construction Services LLC, 11389 Vernon Place, Meadville, PA 16335: On or about 08/08/2025 and at times prior thereto, Employees were exposed to hazards associated with moving the energized 120V temporary receptacle outlet box from the wall before performing drywall work.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2837

1926.405 A02 II B

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 26, 2025
Abate by
Oct 23, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(B): Runs of open conductors were not located where the conductors will not be subject to physical damage. The conductors were not fastened at intervals not exceeding 10 feet (3.05 m); with branch-circuit conductors laid upon the floor.       a.) Accommodative Construction Services LLC, 11389 Vernon Place, Meadville, PA 16335: On or about 08/08/2025 and at times prior thereto, Employees were exposed to hazards associated with  120V temporary receptacle outlet box cords laying on the floor.   ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.