Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ATLANTIC BUILDING SYSTEMS LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ATLANTIC BUILDING SYSTEMS LLC in 3700 S WINDERMERE ST, ENGLEWOOD, CO 80110 (NAICS 332311). OSHA activity number 348428061.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic Building Systems LLC for free Get an email when a new federal OSHA severe-injury report for Atlantic Building Systems LLC is published. One employer, no account, unsubscribe in one click.
Site address
3700 S WINDERMERE ST
City
ENGLEWOOD
State
CO
ZIP
80110
Mailing
3700 S WINDERMERE ST, ENGLEWOOD, CO 80110
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
25
Ownership type
Private (A)

5 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 1, 2025
Abate by
Jan 29, 2026
Penalty
Initial $6,621 · Current $3,973 Reduced

Hazardous substances 8111

29 CFR  1910.95(c)(1):The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average (TWA) sound level of 85 decibels measured on the A scale  (dBA), or equivalently a dose of fifty percent:  (a) On or about August 8, 2025, and at times prior, employees were exposed to noise exceeding a TWA of 88 dBA, a 76% dose during normal operations. The employer did not administer an effective hearing conservation program in that:     (1) The employer did not develop and implement a monitoring program for employee noise exposure.      (2) The employer did not provide an audiometric testing program for employees.     (3) The employer did not provide a selection of hearing protectors for employees to choose from.
Recent events (2)
  • · I (S) $3972.6
  • · Z (S) $6621

1910.95 D01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 1, 2025
Abate by
Jan 29, 2026
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR  1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average (TWA8) of 85 decibels (dBA), the employer did not develop and implement a noise monitoring program:  (a) On or about August 8, 2025, and at times prior, employees who weld and grind steel parts were exposed to noise exceeding a TWA8 of 85 dBA were not included in a noise monitoring program.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.95 G01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 1, 2025
Abate by
Jan 29, 2026
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR  1910.95(g)(1):The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average (TWA8) of 85 decibels (dBA):  (a) On or about August 8, 2025, and at times prior, the employer did not provide baseline and annual audiometric testing for employees who weld and grind steel parts and were exposed to noise exceeding a TWA8 of 85 dBA.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.95 I03

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 1, 2025
Abate by
Jan 7, 2026
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR  1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer:  (a) On or about August 8, 2025, and at times prior, the employer provided one style of hearing protector, foam earplugs, for employees exposed to noise exceeding 85 dBA while welding and grinding steel parts.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.95 K01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 1, 2025
Abate by
Jan 29, 2026
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR  1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k):   (a) On or about August 8, 2025, and at times prior, the employer did not train employees on the selection, fitting, and use of hearing protectors; and the purpose and test procedures for audiometric testing. Employees were exposed to noise above an 8-hour time-weighted average of 85 decibels when welding and grinding steel parts.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Atlantic Building Systems LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348428061.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.