Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLELL CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CLELL CONSTRUCTION, LLC in CORNER OF S. ELMWOOD AVENUE AND W. WASHINGTON STREET, MEDINA, OH 44215 (NAICS 238910). OSHA activity number 348428657.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clell Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Clell Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
CORNER OF S. ELMWOOD AVENUE AND W. WASHINGTON STREET
City
MEDINA
State
OH
ZIP
44215
Mailing
1365 COUNTRY CIRCLE, HARTVILLE, OH 44632
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.652 C02 I

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Aug 26, 2025
Penalty
Initial $1,640 · Current $820 Reduced
29 CFR  1926.652(c)(2)(i):Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer.  On or about August 8, 2025, during the replacement of a water line at a worksite located at the corner of South Elmwood Avenue and West Washington Street, Medina, Ohio, the employer failed to ensure a trench shield was used in accordance with all of the manufacturer's tabulated data specifications, recommendations, and/or limitations.  A GME 2AEX68 Aluminum Extruded Trench Shield was installed in an approximately 7 foot deep trench in a vertical orientation on the trench shield end wall and without pins placed in all of the spreader collar positions.
Recent events (2)
  • — I (O) $820
  • — Z (S) $1640

1926.652 G01 III

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Aug 26, 2025
Penalty
Initial $1,640 · Current $820 Reduced
29 CFR  1926.652(g)(1)(iii):Employees shall be protected from the hazard of cave-ins when entering or exiting the areas protected by shields.  On or about August 8, 2025, during the replacement of a water line at a worksite located at the corner of South Elmwood Avenue and West Washington Street, Medina, Ohio, the employer failed to ensure employees working inside a trench, with a depth of approximately 7 feet, were protected from a cave-in hazard when entering or exiting the area of the trench protected by a trench shield.