MINOT, ND —
OSHA Inspection: RED DEER IRONWORKS USA INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of RED DEER IRONWORKS USA INC. in 210 64TH STEET SE, MINOT, ND 58701 (NAICS 811310). OSHA activity number 348432634.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RED DEER IRONWORKS USA INC.
- Site address
- 210 64TH STEET SE
- City
- MINOT
- State
- ND
- ZIP
- 58701
- Mailing
- 210 64TH STREET SE, MINOT, ND 58701
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 12
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jan 30, 2026
- Abate by
- Mar 6, 2026
- Penalty
- Initial $132,411 · Current $132,411
General-duty citation text
OSH ACT of 1970 Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees who were exposed to struck by hazards: (a) On August 8, 2025, at 210 64th Street SE in Minot, North Dakota, while in the process of conducting the hydrostatic testing of a high pressure hose, the employer failed to ensure that the operator and other employees in the immediate vicinity were protected from inadvertent struck-by hazards. The 15,000 PSI rated hose was pressurized to over 21,000 PSI when the high-pressure hose ruptured. Note: Among other methods, feasible and acceptable abatement methods to correct this hazard include but are not limited to: Expand the existing Standard Operating Procedures for conducting hydrostatic testing to address equipment that cannot fit into the hydro test bay and provide for and require that signs and barricades, or other protective barriers, are placed in a manner and at a distance sufficient to demarcate a safe zone to protect personnel from unanticipated pressure release or equipment failure. The procedures should include a requirement to conduct a Job Hazard Assessment before performing hydrostatic testing to ensure the Standard Operating Procedures can be followed for the assigned task, with clear language stating the testing cannot be conducted unless all of the Standard Operating Procedures are followed and outlining how RDI management will be informed when testing cannot be conducted per the Standard Operating Procedures.
Recent events (2)
- — C (W) $132411
- — Z (W) $132411
More inspections at RED Deer Ironworks USA INC.
View RED Deer Ironworks USA INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348432634.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.