JASPER, GA —
OSHA Inspection: FINLEY'S SERVICES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FINLEY'S SERVICES LLC in 1893 TALKING ROCK ROAD BUILDING 3, JASPER, GA 30143 (NAICS 336999). OSHA activity number 348443029.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FINLEY'S SERVICES LLC
- Site address
- 1893 TALKING ROCK ROAD BUILDING 3
- City
- JASPER
- State
- GA
- ZIP
- 30143
- Mailing
- 1893 TALKING ROCK ROAD BUILDING 3, JASPER, GA 30143
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336999
- Employees
- 13
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 B01
- Issued
- Sep 9, 2025
- Penalty
- Initial $3,972 · Current $1,986 Reduced
General-duty citation text
29 CFR 1910.107(b)(1): The spray booth�was not�substantially constructed�of steel,�securely and�rigidly supported,�or of�concrete or�masonry. a) Paint booth: On or about August 4, 2025, employees performing painting operations were exposed to fire hazards, in that the booth was constructed of plastic sheeting and wooden framing, which do not meet the required construction standards.
Recent events (2)
- — I (S) $1986
- — Z (S) $3972
1910.107 B05 IV
- Issued
- Sep 9, 2025
- Penalty
- Initial $3,972 · Current $1,986 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) Paint booth: On or about August 4, 2025, employees performing painting operations were exposed to fire hazards because the spray booth was not equipped with approved automatic sprinklers on the upstream and downstream sides of the filters.
Recent events (2)
- — I (S) $1986
- — Z (S) $3972
1910.242 B
- Issued
- Sep 9, 2025
- Penalty
- Initial $2,838 · Current $1,419 Reduced
General-duty citation text
29 CFR 1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes: a) Shop: On or about August 14, 2025, employees were exposed to struck-by hazards during cleaning operations. Surfaces, equipment, and personnel were at risk because compressed air was 85 PSI at the output and the nozzles were not protected against "dead-ending."
Recent events (2)
- — I (S) $1419
- — Z (S) $2838
1910.307 C01
- Issued
- Sep 9, 2025
- Penalty
- Initial $3,972 · Current $1,986 Reduced
General-duty citation text
29 CFR 1910.307(c)(1): Equipment and associated wiring not approved as intrinsically safe was permitted in a hazardous location (Classified) location for which it was not approved: a) Paint booth: On or about August 14, 2025, employees were exposed to fire hazards because the relocatable power tap, heater, intake fan, exhaust fan, and lighting inside the paint booth were not intrinsically safe for use in the classified location.
Recent events (2)
- — I (S) $1986
- — Z (S) $3972
1910.334 B01
- Issued
- Sep 9, 2025
- Penalty
- Initial $2,270 · Current $1,135 Reduced
General-duty citation text
29 CFR 1910.334(b)(1): Load rated switches, circuit breakers or other devices specifically designed as disconnecting means were not used for the opening, reversing or closing of electric power and lighting circuits under load conditions: a) Weld shop area, electrical panels: On or about August 14, 2025, employees were exposed to 240V electrical shock and burn hazards during manual switching of the Ingersoll Rand air compressor, performed twice daily. Breaker switch #33 was not rated for routine opening and closing of circuits, creating the hazard.
Recent events (2)
- — I (S) $1135
- — Z (S) $2270
1910.132 D02
- Issued
- Sep 9, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) Shop: On or about August 14, 2025, the employer did not create a written hazard assessment to identify workplace hazards and select appropriate personal protective equipment (PPE) for employee use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C01
- Issued
- Sep 9, 2025
- Penalty
- Initial $271 · Current $136 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Shop: On or about August 14, 2025, employees were exposed to inhalation hazards because respirator use was required but the employer did not create or implement a written respiratory protection program. The program should have included training on proper use, fit testing (qualitative/quantitative), storage, maintenance, medical evaluations, and procedures specific to the worksite.
Recent events (2)
- — I (O) $135.5
- — Z (O) $271
1910.305 G01 IV A
- Issued
- Sep 9, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Assembly area, work bench: On or about August 14, 2025, and on previous occasions, employees were exposed to 120V electrical shock and burn hazards because a relocatable power tap was powered by another relocatable power tap, effectively functioning as permanent wiring. b) Paint booth: On or about August 14, 2025, and on previous occasions, employees were exposed to 120V electrical shock and burn hazards because a relocatable power tap was used as permanent wiring.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348443029.