Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FINLEY'S SERVICES LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FINLEY'S SERVICES LLC in 1893 TALKING ROCK ROAD BUILDING 3, JASPER, GA 30143 (NAICS 336999). OSHA activity number 348443029.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Finley'S Services LLC — free Get an email when a new federal OSHA severe-injury report for Finley'S Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
1893 TALKING ROCK ROAD BUILDING 3
City
JASPER
State
GA
ZIP
30143
Mailing
1893 TALKING ROCK ROAD BUILDING 3, JASPER, GA 30143
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
336999
Employees
13
Ownership type
A

8 citations on file for this inspection.

1910.107 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 9, 2025
Penalty
Initial $3,972 · Current $1,986 Reduced
29 CFR 1910.107(b)(1): The spray booth�was not�substantially constructed�of steel,�securely and�rigidly supported,�or of�concrete or�masonry.  a) Paint booth: On or about August 4, 2025, employees performing painting operations were exposed to fire hazards, in that the booth was constructed of plastic sheeting and wooden framing, which do not meet the required construction standards.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1910.107 B05 IV

Serious Gravity 10 1 instance 13 exposed
Issued
Sep 9, 2025
Penalty
Initial $3,972 · Current $1,986 Reduced
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:   a) Paint booth: On or about August 4, 2025, employees performing painting operations were exposed to fire hazards because the spray booth was not equipped with approved automatic sprinklers on the upstream and downstream sides of the filters.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1910.242 B

Serious Gravity 5 1 instance 13 exposed
Issued
Sep 9, 2025
Penalty
Initial $2,838 · Current $1,419 Reduced
29 CFR 1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes:  a) Shop: On or about August 14, 2025, employees were exposed to struck-by hazards during cleaning operations. Surfaces, equipment, and personnel were at risk because compressed air was 85 PSI at the output and the nozzles were not protected against "dead-ending."
Recent events (2)
  • — I (S) $1419
  • — Z (S) $2838

1910.307 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 9, 2025
Penalty
Initial $3,972 · Current $1,986 Reduced
29 CFR  1910.307(c)(1): Equipment and associated wiring  not approved as intrinsically safe  was permitted in a hazardous location (Classified) location for which it was not approved:   a) Paint booth: On or about August 14, 2025, employees were exposed to fire hazards because the relocatable power tap, heater, intake fan, exhaust fan, and lighting inside the paint booth were not intrinsically safe for use in the classified location.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1910.334 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2025
Penalty
Initial $2,270 · Current $1,135 Reduced
29 CFR 1910.334(b)(1): Load rated switches, circuit breakers or other devices specifically designed as disconnecting means were not used for the opening, reversing or closing of electric power and lighting circuits under load conditions:  a) Weld shop area, electrical panels: On or about August 14, 2025, employees were exposed to 240V electrical shock and burn hazards during manual switching of the Ingersoll Rand air compressor, performed twice daily. Breaker switch #33 was not rated for routine opening and closing of circuits, creating the hazard.
Recent events (2)
  • — I (S) $1135
  • — Z (S) $2270

1910.132 D02

Other-than-serious 1 instance 13 exposed
Issued
Sep 9, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:   a) Shop: On or about August 14, 2025, the employer did not create a written hazard assessment to identify workplace hazards and select appropriate personal protective equipment (PPE) for employee use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C01

Other-than-serious 1 instance 13 exposed
Issued
Sep 9, 2025
Penalty
Initial $271 · Current $136 Reduced
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a) Shop: On or about August 14, 2025, employees were exposed to inhalation hazards because respirator use was required but the employer did not create or implement a written respiratory protection program. The program should have included training on proper use, fit testing (qualitative/quantitative), storage, maintenance, medical evaluations, and procedures specific to the worksite.
Recent events (2)
  • — I (O) $135.5
  • — Z (O) $271

1910.305 G01 IV A

Other-than-serious 2 instances 5 exposed
Issued
Sep 9, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   a) Assembly area, work bench: On or about August 14, 2025, and on previous occasions, employees were exposed to 120V electrical shock and burn hazards because a relocatable power tap was powered by another relocatable power tap, effectively functioning as permanent wiring.  b) Paint booth: On or about August 14, 2025, and on previous occasions, employees were exposed to 120V electrical shock and burn hazards because a relocatable power tap was used as permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348443029.