FRANKLIN PARK, IL —
OSHA Inspection: PACTIV EVERGREEN SERVICES INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PACTIV EVERGREEN SERVICES INC. in 2607 N 25TH AVENUE, FRANKLIN PARK, IL 60131 (NAICS 326199). OSHA activity number 348445503.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACTIV EVERGREEN SERVICES INC.
- Site address
- 2607 N 25TH AVENUE
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
- Mailing
- 2607 N 25TH AVENUE, FRANKLIN PARK, IL 60131
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 217
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Sep 15, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $16,550 · Current $11,585 Reduced
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Thermoforming Department - On August 16, 2025, employees were exposed to machine hazards associated with powered chrome rollers on the C18 extruder. The employer failed to implement energy control application steps as the extruder C018 was not de-energized for the manual cleaning of chrome rolls [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine shutdown [1910.147(d)(2)], machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation or residual energy [1910.147(d)(5)(i), and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $11585
- — Z (S) $16550
More inspections at Pactiv Evergreen Services INC.
View Pactiv Evergreen Services INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348445503.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.