BARNESVILLE, PA ·
OSHA Inspection: LASERTONE CORP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LASERTONE CORP in 1214 MOREA ROAD, BARNESVILLE, PA 18214 (NAICS 337910). OSHA activity number 348455148.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LASERTONE CORP
- Site address
- 1214 MOREA ROAD
- City
- BARNESVILLE
- State
- PA
- ZIP
- 18214
- Mailing
- 1214 MOREA ROAD, BARNESVILLE, PA 18214
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337910
- Employees
- 8
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 21, 2026
- Abate by
- Feb 2, 2026
- Penalty
- Initial $9,268 · Current $6,500 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment that were free from recognized hazards likely to cause death or serious physical harm to employees from struck-by hazards while working in and around the palletized racking system due to the following conditions: a) Warehouse: On or about August 21, 2025, employees were exposed to struck-by hazards while working in and around the palletized racking system due to the palletized racking system not having one or more permanent plaques displaying the maximum permissible load limits. b) Warehouse: On or about August 21, 2025, employees were exposed to struck-by hazards while working in and around the palletized racking system due to visibly damaged sections of the palletized racking system were not isolated until repairs were made. c) Warehouse: On or about August 21, 2025, employees were exposed to struck-by hazards while working in and around the palletized racking system due to at least one upright column installed in such a manner that the baseplate was not fully seated onto the floor without appropriate shims that allow the weight to be distributed across the entire baseplate. Abatement certification and documentation are required.
Recent events (2)
- · I (S) $6500
- · Z (S) $9268
1910.303 B02
- Issued
- Jan 21, 2026
- Abate by
- Feb 9, 2026
- Penalty
- Initial $3,972 · Current $2,768 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) UPS Department: On or about August 21, 2025, employees working in the warehouse were exposed to electrical hazards due to flexible cords connected in series into other electrical cords and relocatable power taps to create extra length and split power to multiple devices. b) FBA Station: On or about August 21, 2025, employees working in the warehouse were exposed to electrical hazards due to flexible cords connected in series into other electrical cords and relocatable power taps to create extra length and split power to multiple devices. Abatement certification required.
Recent events (2)
- · I (S) $2768
- · Z (S) $3972
1910.305 G01 IV A
- Issued
- Jan 21, 2026
- Abate by
- Feb 9, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) UPS Department: On or about August 21, 2025, employees working in the warehouse were exposed to electrical hazards due to flexible cords used in lieu of permeant wiring to power to multiple devices. b) FBA Station: On or about August 21, 2025, employees working in the warehouse were exposed to electrical hazards due to flexible cords used in lieu of permeant wiring to power to multiple devices. Abatement certification required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.132 D02
- Issued
- Jan 21, 2026
- Abate by
- Feb 9, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) Warehouse: On or about August 21, 2025, employees worked in a warehouse receiving and shipping materials and the employer did not maintain any written certification that a hazard assessment was completed. Abatement certification required.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 L06
- Issued
- Jan 21, 2026
- Abate by
- Mar 10, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) Warehouse: On or about August 21, 2025, the employer did not certify that each forklift operator had been trained and evaluated to safely operate such equipment. Abatement certification required.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 337910)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348455148.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.