Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMG RESOURCES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMG RESOURCES in 30 WEST HULLER LANE, READING, PA 19605 (NAICS 423930). OSHA activity number 348458308.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AMG Resources — free Get an email when a new federal OSHA severe-injury report for AMG Resources is published. One employer, no account, unsubscribe in one click.
Establishment
AMG RESOURCES
Site address
30 WEST HULLER LANE
City
READING
State
PA
ZIP
19605
Mailing
30 WEST HULLER LANE, READING, PA 19605
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
44
Ownership type
A

5 citations on file for this inspection.

1910.106 B02 VI B

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Jan 21, 2026
Abate by
Feb 4, 2026
Penalty
Initial $11,823 · Current $11,000 Reduced
29 CFR 1910.106(b)(2)(vi)(b):  Where vent pipe outlets for tanks storing Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), are adjacent to buildings or public ways, they were not located so that the vapors are released at a safe point outside of buildings and horizontally away from closely adjacent walls.   a. The Enviro-Rack Area - On or about August 19, 2025, the 100 gallon gas pumping tank against the metal pole-building was not separated or relief designed to keep flammable relief vapor away from the building resulting in the spread of fire exposing employees to fire and structural collapse struck-by hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $11000
  • — Z (S) $11823

1910.106 G03 IV D

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 21, 2026
Abate by
Feb 4, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.106(g)(3)(iv)(d): Class I flammable dispensing unit(s) were not mounted on a concrete island or protected against collision damage by suitable means.   a. The Enviro-Rack Area - On or about August 19, 2025, the 100 gallon gas pumping tank between the building that caught fire and the enviro-rack was not protected against being struck by forklift and other equipment traffic in the area, exposing employees to a fire or explosion hazard.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Jan 21, 2026
Abate by
Feb 4, 2026
Penalty
Initial $11,823 · Current $11,000 Reduced
29 CFR  1910.178(p)(1):Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  a. The Enviro-Rack Area - On or about August 19, 2025, employees were using the GEHL telehandler all terrain forklift to pick up vehicles to put them onto the Enviro-Rack, the spreader bar that holds fork tines was deformed to the point that it would not sit inside the lock rest which keeps the forks from sliding during operation.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $11000
  • — Z (S) $11823

1910.178 Q01

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Jan 21, 2026
Abate by
Feb 4, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:   a. The Enviro-Rack Area - On or about August 19, 2025, employees were using the GEHL telehandler all terrain forklift to pick up vehicles to put them onto the Enviro-Rack, the spreader bar that holds fork tines was deformed to the point that it would not sit inside the lock rest which keeps the forks from sliding during operation, the forklift was not taken out of service, employees were exposed to struck by hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.307 C

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jan 21, 2026
Abate by
Feb 4, 2026
Penalty
Initial $14,187 · Current $0 Reduced
29 CFR  1910.307(c):Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  a. Enviro-rack area - On or about August 19, 2025, employees were attempting to drain the secondary containment reservoir of the enviro-rack with an unrated sump pump and general service extension cord, which resulted in the ignition of flammable liquids and vapor from the gasoline and vehicle fluids drained on the rack resulting in fire and burn injuries.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14187

View AMG Resources's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348458308.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.