OSHA Inspection: BLATTNER ENERGY, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BLATTNER ENERGY, LLC in 1157 BRECKENRIDGE REPOWER, ENID, OK 73701 (NAICS 237130). OSHA activity number 348459330.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Blattner Energy, LLC — free Get an email when a new federal OSHA severe-injury report for Blattner Energy, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1157 BRECKENRIDGE REPOWER
City
ENID
State
OK
ZIP
73701
Mailing
392 COUNTY ROAD 50, AVON, MN 56310
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
237130
Employees
7082
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 18, 2026
Abate by
Mar 16, 2026
Penalty
Initial $16,550 · Current $16,550
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.   On or about August 19, 2025, at tower #20, an employee was not in use of fall protection while performing repower work from the top platform on an existing wind tower work at a heights greater than 6 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $16550
  • — Z (S) $16550

1926.502 A02

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 18, 2026
Abate by
Mar 16, 2026
Penalty
Initial $16,550 · Current $16,550
29 CFR  1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection.  On or about August 19, 2025,  at tower #20,  an employee was not provided with a fall protection system in place before performing repower work from the top platform on an existing wind tower.
Recent events (3)
  • — F (O) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.502 D15

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 18, 2026
Abate by
Mar 16, 2026
Penalty
Initial $16,550 · Current $16,550
29 CFR  1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  On or about August 19, 2025,  at tower #20,  while performing repower work from the top platform of an existing wind tower four (4) employees shared three (3)  anchorage point that were not capable of supporting at least 5,000 pounds per employee attached.
Recent events (3)
  • — F (O) $16550
  • — C (S) $16550
  • — Z (S) $16550

View Blattner Energy, LLC's full OSHA safety record →