TOMBALL, TX —
OSHA Inspection: PATRIOT ERECTORS, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PATRIOT ERECTORS, LLC. in 20338 TELGE RD. BUILDING H, TOMBALL, TX 77377 (NAICS 332312). OSHA activity number 348475690.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PATRIOT ERECTORS, LLC.
- Site address
- 20338 TELGE RD. BUILDING H
- City
- TOMBALL
- State
- TX
- ZIP
- 77377
- Mailing
- 805 LAS CIMAS PARKWAY SUITE 100 - ATTENTION: WILLIAM RIGBY, AUSTIN, TX 78746
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 15, 2026
- Abate by
- Jan 28, 2026
- Penalty
- Initial $11,350 · Current $11,350
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about August 25, 2025, at the fabrication shop, where employees use a Baileigh Industrial Hydraulic Metal Cutting Band Saw Model BS-916M / Serial Number 22W040213, whose rotating blade was not adequately guarded when cutting metal tubing.
Recent events (1)
- — Z (S) $11350
1910.305 G02 III
- Issued
- Jan 15, 2026
- Penalty
- Initial $8,040 · Current $8,040
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) On or about August 25, 2025, at the fabrication shop, on Baileigh Industrial Hydraulic Metal Cutting Band Saw Model BS-916M / Serial Number 22W040213, strain relief was not present where the power cord attached to the machine.
Recent events (1)
- — Z (S) $8040
More inspections at Patriot Erectors, LLC.