Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ETCO ELECTRIC SUPPLY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ETCO ELECTRIC SUPPLY, INC. in 8791 FRANK DRIVE, MINOCQUA, WI 54548 (NAICS 423610). OSHA activity number 348480534.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Etco Electric Supply, INC. — free Get an email when a new federal OSHA severe-injury report for Etco Electric Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8791 FRANK DRIVE
City
MINOCQUA
State
WI
ZIP
54548
Mailing
8791 FRANK DRIVE, MINOCQUA, WI 54548
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423610
Employees
3
Ownership type
A

3 citations on file for this inspection.

1910.305 B02 I

Serious Gravity 5 8 instances 3 exposed
Issued
Sep 25, 2025
Penalty
Initial $2,563 · Current $1,538 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded.  In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy.  Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.  At an establishment located at 8791 Frank Drive, Minocqua, Wisconsin, in the Old Showroom, employees were exposed to electric and fire hazards from exposed conductors in the following instances;  a.  On or about September 3, 2025, a three-gang light switch box on the western wall of the old showroom did not have a faceplate.   b.  On or about September 3, 2025, a junction box on the western wall of the old showroom did not have a cover.   c. On or about September 3, 2025, a junction box along the southern wall of the Old Showroom did not have a cover.   d. On or about September 3, 2025, a single-gang receptacle box along the southeastern wall of the Old Showroom did not have a faceplate.  e. On or about September 3, 2025, a single-gang receptacle box along the eastern wall of the Old Showroom did not have a faceplate.  f.  On or about September 3, 2025, a single-gang receptacle box along the northeastern wall of the Old Showroom did not have a faceplate.   g. On or about September 3, 2025, a junction box along the northern wall of the Old Showroom did not have a cover.  h. On or about September 3, 2025, a double-gang light switch box on the western wall of the old showroom did not have a faceplate.
Recent events (2)
  • — I (S) $1537.8
  • — Z (S) $2563

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2025
Abate by
Oct 24, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6):The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  On or about September 3, 2025, at an establishment located at 8791 Frank Drive, Minocqua, Wisconsin, the employer did not certify that employees operating the Hyster S50FT LP forklift had been trained and evaluated as required. All employees had prior experience operating forklifts, but the employer could not provide documentation that the employees had been trained on workplace required topics.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 Q01

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2025
Abate by
Oct 24, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(1): Any power-operated industrial truck not in safe operating condition shall be removed from service. All repairs shall be made by authorized personnel.  On or about September 3, 2025, at an establishment located at 8791 Frank Drive, Minocqua, Wisconsin, the Hyster S50FT LP forklift was not removed from service when an issue to the electronic gear shift was identified.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348480534.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.