OSHA Inspection: PRIME CORE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRIME CORE, INC. in N2467 VAUGHAN ROAD, WAUPACA, WI 54981 (NAICS 333511). OSHA activity number 348484320.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prime Core, INC. — free Get an email when a new federal OSHA severe-injury report for Prime Core, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRIME CORE, INC.
Site address
N2467 VAUGHAN ROAD
City
WAUPACA
State
WI
ZIP
54981
Mailing
N2467 VAUGHAN ROAD, WAUPACA, WI 54981
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
333511
Employees
30
Ownership type
A

2 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 5, 2025
Abate by
Jan 6, 2026
Penalty
Initial $5,296 · Current $3,176 Reduced
29 CFR  1910.147(d)(4)(i):  Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.  On or about August 11, 2025, at an establishment located at N2467 Vaughan Road, in Waupaca, Wisconsin, in the North Core Room, a lock out device was not applied to the pneumatic energy source prior to changing out the malfunctioned blow valve on the Lampe 20 core machine exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $3176
  • — Z (S) $5296

1910.147 E02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 5, 2025
Abate by
Jan 6, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.147(e)(2)(i):  The work area shall be checked to ensure that all employees have been safely positioned or removed.  On or about August 11, 2025, at an establishment located at N2467 Vaughan Road, in Waupaca, Wisconsin, in the North Core Room, while testing the functionality of the blow valve on the Lampe 20 core machine, the work area was not cleared to ensure all employees had been safely positioned.  The top portion of the die box traveled in the up position when the equipment was energized exposing employee(s) to caught in between hazards from the upper die box and secure nut.
Recent events (2)