OAK CREEK, WI ·
OSHA Inspection: EDY J RAMOS ANDARA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EDY J RAMOS ANDARA in 710 E. ARTHUR DRIVE, OAK CREEK, WI 53154 (NAICS 238160). OSHA activity number 348484387.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDY J RAMOS ANDARA
- Site address
- 710 E. ARTHUR DRIVE
- City
- OAK CREEK
- State
- WI
- ZIP
- 53154
- Mailing
- 2149 S. 13TH STREET, MILWAUKEE, WI 53215
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1903.19 D01
- Issued
- Dec 3, 2025
- Abate by
- Dec 22, 2025
- Penalty
- Initial $398 · Current $398
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) Edy J Ramos Andara dba Edy J Ramos Andara failed to document abatement within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation 1, Item 1, a serious violation of 29 CFR 1926.501(b)(13) with an abatement date of October 24, 2025. Citation 1, Item 2 a serious violation of 29 CFR 1926.1053(b)(1) with an abatement date of October 9, 2025.
Recent events (1)
- · Z (O) $398
1926.451 G01
- Issued
- Sep 29, 2025
- Abate by
- Oct 24, 2025
- Penalty
- Initial $3,547 · Current $3,547
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) On or about September 4, 2025, at a jobsite located at 710 E. Arthur Dr, Oak Creek, WI, employees were conducting siding installation from a pump jack scaffold, were not protected from falling by a personal fall arrest system or guard rails. This exposed employees to a fall hazard of approximately 13 feet 3 inches to the ground below.
Recent events (1)
- · Z (S) $3547
1926.501 B13
- Issued
- Sep 29, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $2,837 · Current $2,837
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about September 4, 2025 at a job site located at 710 E. Arthur Dr, Oak Creek, WI, the employer had not ensured that employees repairing shingles a residential property were protected from fall hazards therefore, exposing the employees to a fall hazard of approximately 9 feet and 5 inches to the ground.
Recent events (1)
- · Z (S) $2837
1926.1053 B01
- Issued
- Sep 29, 2025
- Abate by
- Oct 9, 2025
- Penalty
- Initial $2,128 · Current $2,128
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. (a) On or about September 4, 2025, at a job site located at 710 E. Arthur Dr, Oak Creek, WI, the employer did not ensure the portable Ladder used by employees to access and egress the residential roof on the back of the home was extended at least three feet above the upper landing, exposing employees to a fall hazard of approximately 8 feet and 11 inches to the ground below.
Recent events (1)
- · Z (S) $2128
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348484387.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.