EL PASO, TX ·
OSHA Inspection: NBS NEW & USED FURNITURE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NBS NEW & USED FURNITURE in 1601 TEXAS AVENUE, EL PASO, TX 79901 (NAICS 337214). OSHA activity number 348486671.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NBS NEW & USED FURNITURE
- Site address
- 1601 TEXAS AVENUE
- City
- EL PASO
- State
- TX
- ZIP
- 79901
- Mailing
- 1601 TEXAS AVENUE, EL PASO, TX 79901
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337214
- Employees
- 6
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1903.19 D01
- Issued
- Jun 3, 2026
- Abate by
- Jul 8, 2026
- Penalty
- Initial $319 · Current $319
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. a.) On or about June 2, 2026, the employer did not submit documentation and Certification of Corrective Action for citation 1 item 2 issued on March 3, 2026, with an abatement due date of May 1, 2026. b.) On or about June 2, 2026, the employer did not submit documentation and Certification of Corrective Action for citation 1 item 9 issued on March 3, 2026, with an abatement due date of May 1, 2026.
Recent events (1)
- · Z (O) $319
1910.22 A01
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,972 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1):29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. On or about September 05, 2025, on the eastside of the facility; employees utilized machines and work areas while assembling furniture with a build up of saw dust refuse that was not kept in a clean, orderly and sanitary condition.
Recent events (2)
- · I (S) $2000
- · Z (S) $3972
1910.134 C01
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,972 · Current $2,000 Reduced
General-duty citation text
9 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer: On or about September 05, 2025, on the eastside of the facility, the employer did not ensure that a written respiratory protection program was established and implemented while assembling furniture.
Recent events (2)
- · I (S) $2000
- · Z (S) $3972
1910.213 D01
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,405 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.213(d)(1):Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: On or about September 05, 2025, at the eastside of the facility; employees utilized a circular table saw that was not guarded while assembling furniture.
Recent events (2)
- · I (S) $1500
- · Z (S) $3405
1910.303 B02
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,405 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about September 05, 2025, at the eastside of the facility; employees utilized electrical equipment that was not used or installed in accordance with instructions while assembling furniture
Recent events (2)
- · I (S) $1500
- · Z (S) $3405
1910.305 B02 I
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,405 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about September 05, 2025, at the eastside of the facility; employees utilized outlets that did not have a faceplate while assembling furniture.
Recent events (2)
- · I (S) $1500
- · Z (S) $3405
1910.305 G01 IV A
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,405 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about September 05, 2025, on the eastside of the facility, employees utilized equipment with flexible cords and cables that were used as a substitute for fixed wiring while assembling furniture.
Recent events (2)
- · I (S) $1500
- · Z (S) $3405
1910.305 H06
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,405 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(h)(6):Fittings. Connectors used to connect lengths of cable in a run shall be of a type that lock firmly together. Provisions shall be made to prevent opening or closing these connectors while energized. Strain relief shall be provided at connections and terminations. On or about September 05, 2025, on the eastside of the facility; employees utilized power cords with damaged strain relief while assembling furniture in the following instances: a) On the production floor, a multi-outlet strip that powered the microwave had a damaged strain relief. b) On the production floor, a relocatable power tap (RPT) powering a radio and a multi-outlet strip had a damaged strain relief. c) On the production floor, a pinch roller had a damaged strain relief. d) On the spray floor, a pendent electrical box had a damaged strain relief.
Recent events (2)
- · I (S) $1500
- · Z (S) $3405
1910.334 A02 II
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,405 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: On or about September 05, 2025, on the eastside of the facility, the employer did not ensure electrical equipment was not defective or damaged while assembling furniture.
Recent events (2)
- · I (S) $1500
- · Z (S) $3405
1910.1200 E01
- Issued
- Mar 3, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $3,972 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On September 05, 2025, on the eastside of the facility, the employer did not develop, implement, and maintain at the workplace a written hazard communication program while assembling furniture.
Recent events (2)
- · I (S) $2000
- · Z (S) $3972