ELK GROVE VILLAGE, IL ·
OSHA Inspection: MAPES & SPROWL STEEL LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of MAPES & SPROWL STEEL LLC in 1100 EAST DEVON AVENUE, ELK GROVE VILLAGE, IL 60007 (NAICS 333519). OSHA activity number 348487521.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAPES & SPROWL STEEL LLC
- Site address
- 1100 EAST DEVON AVENUE
- City
- ELK GROVE VILLAGE
- State
- IL
- ZIP
- 60007
- Mailing
- 1100 EAST DEVON AVENUE, ELK GROVE VILLAGE, IL 60007
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333519
- Employees
- 50
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.215 A04
- Issued
- Jan 12, 2026
- Penalty
- Initial $4,220 · Current $4,220
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Metal Core Department - On or about September 5, 2025, the employer did not ensure that a work rest was in place and properly adjusted to no more than a 1/8 inch opening to support offhand grinding work on equipment, such as the Palmgren PowerGrind 6" bench grinder. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $4220
1910.215 B09
- Issued
- Jan 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Metal Core Department - On or about September 5, 2025, the employer did not ensure that the tongue guards on the Palmgren PowerGrind 6" Bench Grinder were properly adjusted to not exceed one fourth of an inch. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- Jan 12, 2026
- Penalty
- Initial $4,220 · Current $4,220
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Metal Core Department - On or about September 5, 2025, the employer did not ensure that all electrical equipment was installed and used in accordance with the listing and labeling. A yellow extension cord was connected in series (daisy chained) to supply power to a power strip. The power strip was used to supply power to a blue and orange extension cord, that was used to power an orange extension cord and a portable fan. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $4220
1910.212 A01
- Issued
- Jan 12, 2026
- Penalty
- Initial $13,240 · Current $13,240
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Metal Core Department- On or about September 5, 2025, the employer did not ensure that employees were adequately protected from hazards created by rotating parts, such as the unused portions of the Amada HA-250 Horizontal Band Saw blade. Mapes & Sprowl Steel LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(1), which was contained in OSHA inspection number 1783181, citation number 1, item number 2, and was affirmed as a final order on April 8, 2025, with respect to a workplace located at 1100 East Devon Avenue, Elk Grove Village, Illinois. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (R) $13240
More inspections in this industry (NAICS 333519)