Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NANKANI & SONS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of NANKANI & SONS, INC. in 10221 PRAIRIE CREEK LANE, CONROE, TX 77384 (NAICS 561790). OSHA activity number 348493941.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nankani & Sons, INC. — free Get an email when a new federal OSHA severe-injury report for Nankani & Sons, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10221 PRAIRIE CREEK LANE
City
CONROE
State
TX
ZIP
77384
Mailing
7787 PINEMONT DRIVE, HOUSTON, TX 77040
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
561790
Employees
4
Ownership type
A

5 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 6, 2026
Abate by
Mar 25, 2026
Penalty
Initial $11,585 · Current $11,585
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  On or about September 8, 2025, at various jobsites where employees worked on pool electrical equipment without having employer provided  safety-related work practices training.
Recent events (2)
  • — I (S) $11585
  • — Z (S) $11585

1910.333 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 6, 2026
Abate by
Mar 25, 2026
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not deenergized before the employee works on or near them.  On or about September 8, 2025, at a residence in Conroe, TX where an employee was changing out a pool light without deenergizing the sub panel that powered the light.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1910.333 B02 IV B

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 6, 2026
Abate by
Mar 25, 2026
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR 1910.333(b)(2)(iv)(B): Before circuits or equipment was worked as deenergized, a qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees would be exposed and did not verify that the circuit elements and equipment parts were deenergized:  On or about September 8, 2025, at a residence in Conroe, TX where an employee was changing out a pool light without testing to ensure circuit elements in the sub panel he was working in were deenergized.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1910.333 B02 II A

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 6, 2026
Abate by
Mar 25, 2026
Penalty
Initial $11,585 · Current $11,585
29 CFR 1910.333(b)(2)(ii)(A): Safe procedures for deenergizing circuits and equipment were not determined before circuits or equipment are deenergized.  On or about September 8, 2025, at a residence in Conroe, TX where an employee was changing out a pool light before safe procedures for deenergizing were determined.
Recent events (2)
  • — I (S) $11585
  • — Z (S) $11585

1910.333 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 6, 2026
Abate by
Mar 25, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2)(iii):  On or about September 8, 2025, at a residence in Conroe, TX where an employee was changing out a pool light without locking or tagging out the pool light breaker that was deenergized.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348493941.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.