Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUBCOM CABLE SYSTEMS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUBCOM CABLE SYSTEMS, LLC in 100 PISCATAQUA DR, NEWINGTON, NH 03801 (NAICS 517919). OSHA activity number 348497322.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Subcom Cable Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Subcom Cable Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
100 PISCATAQUA DR
City
NEWINGTON
State
NH
ZIP
03801
Mailing
100 PISCATAQUA DR, NEWINGTON, NH 03801
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517919
Employees
850
Ownership type
A

3 citations on file for this inspection.

1910.23 C11

Serious Gravity 5 1 instance 30 exposed
Issued
Jan 20, 2026
Abate by
Feb 13, 2026
Penalty
Initial $14,188 · Current $4,250 Reduced
29 CFR  1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface.  Pan Building - Cable turning employees using portable hook on ladders to enter and exit the pans were not protected from a fall of up to 7 feet where the portable hook on ladders did not have side rails extending three feet above the landing surface.
Recent events (2)
  • — I (S) $4250
  • — Z (S) $14188

1910.179 N03 VI

Serious Gravity 10 1 instance 50 exposed
Issued
Jan 20, 2026
Abate by
Jan 26, 2026
Penalty
Initial $16,550 · Current $7,000 Reduced
29 CFR  1910.179(n)(3)(vi): The employer did not require that the operator of crane(s) avoid carrying loads over people:  Pan Building- Employees are not protected from struck by hazards where the 110-ton gantry crane moves pans over the heads of employees working in the building. On or about September 6, 2025, an employee was struck by the superstructure of the 110-ton gantry crane when it entered the Run Over Department without stopping and ensuring that no one was in the area while it moved a pan to the North door. On or about September 11, 2025, an employee moved a pan through the Run Over Department with the 110-ton gantry crane over the heads of employees while going to the North door during the onsite OSHA inspection.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $16550

1910.135 A01

Serious Gravity 5 1 instance 16 exposed
Issued
Jan 20, 2026
Abate by
Jan 26, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.135(a)(1):The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects:  Pan Building - Employees working on the pan crew are not protected from head injuries where head protection is not required to be worn while working under and near the 110-ton gantry crane and it's suspended loads.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Subcom Cable Systems, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348497322.