Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NUGENT STEEL AND SUPPLY COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NUGENT STEEL AND SUPPLY COMPANY, INC. in 1800 S. WESTPORT DRIVE, PORT ALLEN, LA 70767 (NAICS 213112). OSHA activity number 348504671.

Watch Nugent Steel AND Supply Company, INC. — free Get an email when a new federal OSHA severe-injury report for Nugent Steel AND Supply Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1800 S. WESTPORT DRIVE
City
PORT ALLEN
State
LA
ZIP
70767
Mailing
P.O. BOX 730, PORT ALLEN, LA 70767
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
32
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 21, 2026
Abate by
Feb 9, 2026
Penalty
Initial $6,620 · Current $6,620
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard from flying polyvinyl chloride (PVC) pipe fragments:   a) On or about September 15, 2025 the employer  used schedule 80 polyvinyl chloride (PVC) piping  to transport compressed air to pneumatically powered equipment and machinery, exposing employees to a struck-by hazard from flying PVC pipe fragments associated with such use of PVC piping in above ground installations located in the shop area.
Recent events (2)
  • — I (S) $6620
  • — Z (S) $6620

1910.212 A03 II

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jan 21, 2026
Penalty
Initial $6,620 · Current $4,634 Reduced
29 CFR  1910.212(a)(3)(ii):The  point of operation of machines whose operation exposed an employee to injury, was not guarded.  On or about September 15, 2025. An employee performed tasks in the shop building one and used the circular saw without the point of operation having a guard.
Recent events (2)
  • — I (O) $4634
  • — Z (S) $6620

1910.335 B02

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jan 21, 2026
Abate by
Feb 9, 2026
Penalty
Initial $8,276 · Current $0 Reduced
29 CFR  1910.335(b)(2):Barricades were not used in conjunction with safety signs where it was necessary to prevent or limit employee access to work areas in which employees were exposed to uninsulated energized conductors or circuit parts:  A) On or about September 15, 2025 employees were exposed to active 208v and 408v, energized breaker panels with cover removed in the shop area with no barricades used to limit employee access to work areas with exposure to uninsulated energized conductors or circuit parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8276

1910.253 B02 II

Other-than-serious 1 instance 5 exposed
Issued
Jan 21, 2026
Penalty
Initial $930 · Current $930
29 CFR  1910.253(b)(2)(ii):Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  a) on or about September 15, 2025  an oxygen cylinder was not secured from falling objects or being knocked over in the shop area near the Python machine.
Recent events (2)
  • — I (O) $930
  • — Z (O) $930

1910.334 A02 I

Deleted Other-than-serious 1 instance 1 exposed
Issued
Jan 21, 2026
Abate by
Feb 9, 2026
Penalty
Initial $930 · Current $0 Reduced
29 CFR  1910.334(a)(2)(i):1910.334(a)(2)(i):  Portable cord and plug connected electric equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):     a) On or about November 8, 2023, employees utilized damaged extension cords in the following location: north side, an employee used a Dewalt Dwe 402 grinder which showed damage to the outer sheathing of the cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $930

1910.305 G02 III

Other-than-serious 2 instances 3 exposed
Issued
Jan 21, 2026
Abate by
Feb 9, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints and/or terminal screws.      On or about September 15, 2025, employees utilized damaged extension cords in the following location: North side, an employee used an  extension cord which showed damage to the outer sheathing connected to a floor fan. South side, an employee used an extension cord which showed damage to the outer sheathing connected to a Dewalt DWE-402 grinder.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nugent Steel AND Supply Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348504671.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.