Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COUNTERTOP DESIGN INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COUNTERTOP DESIGN INC. in 3630 REESE AVE SUITE A, WEST PALM BEACH, FL 33404 (NAICS 327991). OSHA activity number 348505827.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Countertop Design INC. — free Get an email when a new federal OSHA severe-injury report for Countertop Design INC. is published. One employer, no account, unsubscribe in one click.
Site address
3630 REESE AVE SUITE A
City
WEST PALM BEACH
State
FL
ZIP
33404
Mailing
3630 REESE AVE SUITE A, WEST PALM BEACH, FL 33404
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
327991
Employees
8
Ownership type
A

9 citations on file for this inspection.

1910.178 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2026
Penalty
Initial $2,270 · Current $1,362 Reduced
29 CFR  1910.178(a)(4):Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, employees were exposed to a struck by hazard while using a Toyota Forklift Truck (Model No. 7FGCU25, Serial No. 76329) with an attachment without prior written approval from the manufacture and without an updated capacity plate.
Recent events (2)
  • — I (S) $1362
  • — Z (S) $2270

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 6, 2026
Abate by
Apr 20, 2026
Penalty
Initial $3,972 · Current $2,383 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, an employee was exposed to an amputation and struck by hazard created by the point of operation and flying chips while operating a Tecno MBM (Model America, serial No. 3298) that lacked guarding.
Recent events (2)
  • — I (S) $2383.2
  • — Z (S) $3972

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 6, 2026
Penalty
Initial $2,270 · Current $1,362 Reduced
29 CFR  1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:   a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, an employee was exposed to an amputation hazard while using a Powermatic table saw (Model No. 72, Serial No. 7872069) that lacked a guard over the blade while cutting a wooden two-by-four.
Recent events (2)
  • — I (S) $1362
  • — Z (S) $2270

1910.213 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2026
Penalty
Initial $1,702 · Current $1,021 Reduced
29 CFR  1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: Note:  The spreader in connection with grooving, dadoing, or rabbeting is not required.   a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, an employee was exposed to a struck-by hazard while using a Powermatic table saw (Model No. 72, Serial No. 7872069) that lacked an anti-kickback device and spreader while cutting a wooden two-by-four.
Recent events (2)
  • — I (S) $1021.2
  • — Z (S) $1702

1910.213 C03

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, an employee was exposed to a struck-by hazard while using a Powermatic table saw (Model No. 72, Serial No. 7872069) that lacked an anti-kickback device and spreader while cutting a wooden two-by-four.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2026
Penalty
Initial $1,447 · Current $868 Reduced
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, an employee was exposed to an electrical shock hazard due to using an extension cord that lacked strain relief.
Recent events (2)
  • — I (S) $868.2
  • — Z (S) $1447

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):   a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, the employer failed to inspect electrical equipment and flexible cords for defects, as evidenced by extension cords lacking strain relief and fans with missing ground pins, thereby exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(3)(i): A flexible cord used with grounding-type equipment shall contain an equipment grounding conductor:   a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, an employee was exposed to an electrical shock hazard due to working with a fan that lacked a ground pin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 2 exposed
Issued
Mar 6, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) On or about September 15, 2026, at the jobsite located at 3630 Reese Ave Suite A, WEST PALM BEACH, FL 33404, the employer did not ensure a fire extinguisher was mounted and identified, there by exposing employees to possible fire related injuries such as smoke inhalation and burns.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Countertop Design INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348505827.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.