Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STEELCELL OF NORTH AMERICA, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STEELCELL OF NORTH AMERICA, LLC in 510 INDUSTRIAL PARK ROAD, BALDWIN, GA 30511 (NAICS 332311). OSHA activity number 348511247.

Watch Steelcell OF North America, LLC — free Get an email when a new federal OSHA severe-injury report for Steelcell OF North America, LLC is published. One employer, no account, unsubscribe in one click.
Site address
510 INDUSTRIAL PARK ROAD
City
BALDWIN
State
GA
ZIP
30511
Mailing
510 INDUSTRIAL PARK ROAD, BALDWIN, GA 30511
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.134 A02

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $5107.00 · Current $3064.00 Reduced

Hazardous substances 0430

29 CFR  1910.134(a)(2): A respirator was not provided by the employer to each employee when such equipment was necessary to protect the health of the employee:   a)Top coating room - On or about September 10, 2025 and at times prior, the employer exposed employees to respiratory hazards in that, the employer failed to ensure the respiratory protections were provided to employee using Methyl Ethyl Ketone (MEK) while flushing the paint line at the end of the shift.
Recent events (2)
  • — I (S) $3064.2
  • — Z (S) $5107

1910.252 B02 III

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6809.00 · Current $6809.00
29 CFR  1910.252(b)(2)(iii):Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) Production Floor/Welding area- On or about September 16, 2025, and at times prior, the employer exposed employees to health hazards associated with ultraviolet (UV) radiation and welding rays in that, the employer failed to ensure workers and other workers adjacent to welding area were protected from the rays by a flameproof screen.
Recent events (2)
  • — I (O) $6809
  • — Z (S) $6809

1910.1000 A

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $11916.00 · Current $7150.00 Reduced

Hazardous substances 2610

29 CFR 1910.1000(a):  The employer shall ensure that no employee is exposed to any substance at a level in excess of the exposure limit given for that substance in Table Z-1 of this standard.  a) Welding area, on September 24, 2025, the employer exposed employees to health hazards associated with Zinc Oxide fume in that, the employer failed to ensure that employees were not exposed to Zinc Oxide fume at a concentration exceeding the OSHA PEL of 5 mg/m� when  air sampling conducted for welding employees indicated exposure level of 8.16 mg/m3.