OSHA Inspection: GIESBRECHT PLUMBING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GIESBRECHT PLUMBING in W. HEFFNER ROAD AND N. PENNSYLVANIA AVE., OKLAHOMA CITY, OK 73120 (NAICS 238220). OSHA activity number 348512542.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Giesbrecht Plumbing — free Get an email when a new federal OSHA severe-injury report for Giesbrecht Plumbing is published. One employer, no account, unsubscribe in one click.
Establishment
GIESBRECHT PLUMBING
Site address
W. HEFFNER ROAD AND N. PENNSYLVANIA AVE.
City
OKLAHOMA CITY
State
OK
ZIP
73120
Mailing
8070 N GLADE, OKLAHOMA CITY, OK 73132
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238220
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Mar 30, 2026
Penalty
Initial $4,965 · Current $4,392 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  On or about September 18, 2025, on the corner of Hefner and North Pennsylvania Ave., employees were not in use of protective head gear while working in an excavation installing a water line and locating leaks.
Recent events (1)
  • — Z (S) $4965

1926.501 B07 I

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Mar 30, 2026
Penalty
Initial $4,965 · Current $4,468 Reduced
29 CFR 1926.501(b)(7)(i): Each employee at the edge of an excavation 6 feet (1.8 m) or more in depth was not protected from falling by guardrail systems, fences, or barricades when the excavations were not readily seen because of plant growth or other visual barrier:  On or about September 18, 2025, at the corner of Hefner and North Pennsylvania Ave., employees working near the edge of an excavation greater than 6 feet in depth installing a water line are not protected from falling into the excavation.
Recent events (1)
  • — Z (S) $4965

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Mar 30, 2026
Penalty
Initial $4,965 · Current $4,468 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  On or about September 18, 2025, at the corner of Hefner and North Pennsylvania Ave., employees locating water leaks  within an excavation greater than 18 feet deep used a  10-foot ladder for access and egress.
Recent events (1)
  • — Z (S) $4965

1926.651 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Mar 30, 2026
Penalty
Initial $4,965 · Current $4,468 Reduced
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  On or about September 18, 2025, on the corner of Hefner and North Pennsylvania Ave., employees worked within an excavation installing a water line and locating leaks when spoil piles were placed within two (2) feet of the excavation edge.
Recent events (1)
  • — Z (S) $4965

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Mar 17, 2026
Penalty
Initial $4,965 · Current $4,468 Reduced
29 CFR 1926.651(k)(1):  Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.  An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift.  Inspections shall also be made after every rainstorm or other hazard increasing occurrence.  These inspections are only required when employee exposure can be reasonably anticipated:  On or about September 18, 2025, on the corner of Hefner and North Pennsylvania Ave., a competent person did not conduct an inspection of an excavation before employees performed water line installation and  leak location activities  to ensure conditions did not exist that could result in a possible cave-in.
Recent events (1)
  • — Z (S) $4965

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Mar 30, 2026
Penalty
Initial $4,965 · Current $4,468 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).  On or about September 18, 2025, on the corner of Hefner and North Pennsylvania Ave., employees installing a water line and locating leaks within an excavation more than 5 feet deep were not protected from cave-ins by a protective system.
Recent events (1)
  • — Z (S) $4965

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Mar 30, 2026
Penalty
Initial $4,965 · Current $4,468 Reduced
29 CFR 1926.1053(b)(1):  A portable ladder used for access to an upper landing surface did not have the ladder side rails extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, shall be provided to assist employees in mounting and dismounting the ladder.  In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about September 18, 2025, on the corner of Hefner and North Pennsylvania Ave.,  employees installing water lines and locating leaks did not use a ladder that extended at least 3 feet beyond the upper landing of the excavation.
Recent events (1)
  • — Z (S) $4965

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348512542.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.