OSHA Inspection: UNITED REMODELING INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNITED REMODELING INC in 6202 CHUCK LANE, EAU CLAIRE, WI 54703 (NAICS 238160). OSHA activity number 348515123.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Remodeling INC — free Get an email when a new federal OSHA severe-injury report for United Remodeling INC is published. One employer, no account, unsubscribe in one click.
Site address
6202 CHUCK LANE
City
EAU CLAIRE
State
WI
ZIP
54703
Mailing
4785 PEGGY LANE, WHITE BEAR LAKE, MN 55110
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 22, 2025
Abate by
Oct 14, 2025
Penalty
Initial $1,702 · Current $1,702
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) Commercial building rooftop, various locations; On or about September 18, 2025, employees were not required to wear eye protection to protect against flying particles while operating pneumatic nail guns to affix asphalt shingles using 1-1/4-inch coil roofing nails.
Recent events (1)
  • — Z (S) $1702

1926.501 B11

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 22, 2025
Abate by
Oct 14, 2025
Penalty
Initial $3,405 · Current $3,405
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  (a) Commercial building rooftop, various locations; On or about September 18, 2025, and dates prior, employees were not protected from falls, while engaged in roofing replacement activities from a steep-slope roof, and near edges, while working at approximate heights of up to 10.5 feet above ground level.
Recent events (1)
  • — Z (S) $3405

1926.503 A01

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 22, 2025
Abate by
Oct 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   (a) Commercial building rooftop, various locations; On or about September 18, 2025, and dates prior, the employer did not provide training on applicable topics, including but not limited to, fall hazard recognition and mitigation procedures, regarding employees who were not protected from falls while engaged in roofing replacement activities from a steep-slope roof at approximate heights of up to 10.5 feet above ground level.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 22, 2025
Penalty
Initial $1,929 · Current $1,929
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) Commercial building rooftop, west side; On or about September 18, 2025, and dates prior, a 24-foot Keller brand fiberglass extension ladder was leaned against the west-facing eave and was used for rooftop access/egress where the landing surface was approximately 10.5 feet above ground-level.  The upper side rails of the ladder did not extend at least 3-feet above the landing surface.