AKRON, OH —
OSHA Inspection: SOLID SHIELD ROOFING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SOLID SHIELD ROOFING LLC in 1216 DELOS ST, AKRON, OH 44306 (NAICS 238160). OSHA activity number 348521527.
Where did this inspection happen?
- Establishment
- SOLID SHIELD ROOFING LLC
- Site address
- 1216 DELOS ST
- City
- AKRON
- State
- OH
- ZIP
- 44306
- Mailing
- 1709 MAPLE AVE NE, CANTON, OH 44705
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $3972.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about , September 23, 2025, during a roofing project located at 1216 Delos ST, Akron Ohio 44306; the employer did not ensure that employees on the roof were protected from a fall of 10.7 feet by utilizing guardrail systems, safety net system, personal fall arrest system, or alternative fall protection measures.
Recent events (2)
- — I (S) $1500
- — Z (S) $3972
1926.1053 B01
- Issued
- Penalty
- Initial $3972.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: On or about September 23, 2025, employees were observed using a ladder during the roofing operations on a residential structure located at 1216 Delos ST, Akron Ohio 44306; the employer did not ensure the ladder side rails were extended at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access to the roof.
Recent events (2)
- — I (S) $1500
- — Z (S) $3972
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348521527.