Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MATERIA MILLWORK LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MATERIA MILLWORK LLC in 254 BODWELL STREET UNIT B, AVON, MA 02322 (NAICS 337110). OSHA activity number 348522467.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Materia Millwork LLC — free Get an email when a new federal OSHA severe-injury report for Materia Millwork LLC is published. One employer, no account, unsubscribe in one click.
Site address
254 BODWELL STREET UNIT B
City
AVON
State
MA
ZIP
02322
Mailing
254 BODWELL STREET UNIT B, AVON, MA 02322
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337110
Employees
5
Ownership type
A

7 citations on file for this inspection.

1910.212 B

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Mar 10, 2026
Penalty
Initial $2,128 · Current $1,064 Reduced
29 CFR  1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  Location: Workshop  On or about September 29, 2025, the Ridgid drill press was not anchored to the floor to prevent walking of the drill press.
Recent events (2)
  • — I (O) $1064
  • — Z (S) $2128

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 10, 2026
Penalty
Initial $3,547 · Current $1,774 Reduced
29 CFR  1910.213(c)(1):Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Location: Carpentry Shop  On or about September 24, 2025 the table saw did not had a hood guard.
Recent events (2)
  • — I (S) $1773.5
  • — Z (S) $3547

1910.213 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 10, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(2):Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:  Location: Carpentry Shop  On or about September 24, 2025, the table saw did not have a splitter on the saw to prevent anti kickbacks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 10, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(3):Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  Location: Carpentry Shop  On or about September 24, 2025, the table saw was not equipped with anti kickback fingers to to prevent anti kickbacks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Mar 10, 2026
Abate by
Apr 28, 2026
Penalty
Initial $2,128 · Current $1,064 Reduced
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   Location Carpenter Shop  On or about September 24, 2025, the employer did not maintain clear access to the electrical panels.
Recent events (2)
  • — I (O) $1064
  • — Z (S) $2128

1910.37 A04

Deleted Other-than-serious 1 instance 3 exposed
Issued
Mar 10, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(4):Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  Location: Carpenter Shop  On or about September 24, 2025,  emergency exit light leading to the outside was not operational.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E01

Deleted Other-than-serious 1 instance 2 exposed
Issued
Mar 10, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(1):The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  Location: Carpenter shop  On or about September 24, 2025, the employer did not inspect fire extinguishers in the carpenter shop.