Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PURSELL AGRI-TECH, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PURSELL AGRI-TECH, LLC in 1600 EAST PRESIDENT STREET, SAVANNAH, GA 31404 (NAICS 325314). OSHA activity number 348524554.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pursell Agri-Tech, LLC — free Get an email when a new federal OSHA severe-injury report for Pursell Agri-Tech, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1600 EAST PRESIDENT STREET
City
SAVANNAH
State
GA
ZIP
31404
Mailing
104 CALHOUN AVE., SYLACAUGA, AL 35150
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325314
Employees
15
Ownership type
A

4 citations on file for this inspection.

1910.29 B13 I

Serious Gravity 5 2 instances 3 exposed
Issued
Mar 11, 2026
Abate by
Apr 13, 2026
Penalty
Initial $6,621 · Current $3,973 Reduced
29 CFR  1910.29(b)(13)(i): The guardrail system opening used around holes that serve as points of access (such as ladderways),  did not have a self-closing gate that slides or swings away from the hole, and equipped with a top rail and mid rail or equivalent intermediate member that met the requirements in paragraph (b) of this section.  (a) Third floor of the coating area - On or about September 24, 2025, and at times prior to, the employer exposed employees to a fall hazard, in that the guardrail system was not equipped with a self-closing gate for the ladderway on the elevated catwalk for the recirculation conveyor with a 9' fall to floor distance.  (b) First floor of the coating area - On or about September 24, 2025, and at times prior to, the employer exposed employees to fa fall hazard, in that the guardrail system was not equipped with a self-closing gate for the ladderway on the elevated catwalk for the Line 2 cooler with a 53" fall to floor distance.
Recent events (2)
  • — I (S) $3972.6
  • — Z (S) $6621

1910.23 C02

Serious Gravity 5 2 instances 3 exposed
Issued
Mar 11, 2026
Abate by
Apr 13, 2026
Penalty
Initial $5,296 · Current $3,178 Reduced
29 CFR 1910.23(c)(2): The employer did not ensure that each stepladder or combination ladder used in a stepladder mode is equipped with a metal spreader or locking device that securely holds the front and back sections in an open position while the ladder is in use.  a) On the first floor of the coating area - On or about September 24, 2025, the employer exposed employees to a fall hazard, in that employees used a stepladder that had bent metal spreaders and did not securely lock the ladder in an open position.  b) On the second floor of the coating area - On or about September 24, 2025, the employer exposed employees to a fall hazard, in that employees used a stepladder that had bent metal spreaders and did not securely lock the ladder in an open position.
Recent events (2)
  • — I (S) $3177.6
  • — Z (S) $5296

1910.157 C01

Other-than-serious 1 instance 15 exposed
Issued
Mar 11, 2026
Abate by
Apr 13, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  (a) Throughout the facility - On or about September 24, 2025, the employer exposed employees to fire hazards, in that each fire extinguisher was not mounted with its location identified so it was readily accessible to employees in an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G02 I

Other-than-serious 1 instance 2 exposed
Issued
Mar 11, 2026
Abate by
Apr 13, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i).  (a) Second floor of the coating area - On or about September 24, 2025, the employer exposed employees to electrical shock hazards, in that all electrical control panels were not closed and secured to guard against accidental contact with live parts inside.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348524554.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.