BARRINGTON, IL —
OSHA Inspection: MS BROTHERS CONSTRUCTION CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MS BROTHERS CONSTRUCTION CORP. in 1011 PRAIRIE AVE., BARRINGTON, IL 60010 (NAICS 238130). OSHA activity number 348530478.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MS BROTHERS CONSTRUCTION CORP.
- Site address
- 1011 PRAIRIE AVE.
- City
- BARRINGTON
- State
- IL
- ZIP
- 60010
- Mailing
- 1111 SOLFISBURG AVE., AURORA, IL 60505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Sep 29, 2025
- Abate by
- Nov 17, 2025
- Penalty
- Initial $3,972 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On September 29, 2025, employees engaged in framing carpentry work to a newly built residential structure were not protected from fall hazards while working at elevations approximately 23 feet above the ground. b) On September 29, 2025, employees engaged in framing carpentry work on the second story of a newly built residential structure were not protected from fall hazards of unguarded windows and wall openings approximately 15.5 feet above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.