BRIDGEHAMPTON, NY —
OSHA Inspection: COPPER SOLUTIONS CORP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of COPPER SOLUTIONS CORP in 114 ROSE WAY, BRIDGEHAMPTON, NY 11932 (NAICS 238160). OSHA activity number 348541855.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COPPER SOLUTIONS CORP
- Site address
- 114 ROSE WAY
- City
- BRIDGEHAMPTON
- State
- NY
- ZIP
- 11932
- Mailing
- 2 SANDLEWOOD CT, HAMPTON BAYS, NY 11946
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 35
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B04
- Issued
- Mar 30, 2026
- Penalty
- Initial $8,276 · Current $8,276
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). Location: 114 Rose Way Bridgehampton, NY 11932. On or about October 3rd, 2025- Employees were exposed to falling while removing old plywood on a residential home while working from a ladder-jack scaffold platform. The scaffold plank did not extend at least 6 inches over the centerline of the support. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
- — Z (S) $8276
1926.451 E01
- Issued
- Mar 30, 2026
- Penalty
- Initial $8,276 · Current $8,276
General-duty citation text
29 CFR 1926.451(e)(1): scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Cross braces shall not be used as a means of access. Location: 114 Rose Way Bridgehampton, NY 11932. On or about October 03rd, 2025-A ladder was not provided to access a ladder-jack scaffold platform. Employees were using the ladder supporting the prank to access the working level exposing the employees to fall hazards of approximately 15 feet. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
- — Z (S) $8276
1926.451 G01 I
- Issued
- Mar 30, 2026
- Penalty
- Initial $8,276 · Current $8,276
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system. Location: 114 Rose Way Bridgehampton, NY 11932. On or about October 03rd, 2025- Employees were not protected from falling approximately 15 feet to the ground below while installing removing old siding and plywood working from ladder-jack scaffolding; Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
- — Z (S) $8276
1926.1053 B01
- Issued
- Mar 30, 2026
- Penalty
- Initial $8,276 · Current $8,276
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. Location: 114 Rose Way Bridgehampton, NY 11932. On or about 10/02/2025, employees were accessing the roof of a residential home by using an aluminum extension ladder that was only extended 1ft above the landing. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
- — Z (S) $8276
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348541855.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.