Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PASCUAL SILVA, JR. DBA SILVA'S PAINTING AND RENOVATIONS LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of PASCUAL SILVA, JR. DBA SILVA'S PAINTING AND RENOVATIONS LLC in ALLEY BEHIND 4412 W. 44TH ST., CHICAGO, IL 60632 (NAICS 238320). OSHA activity number 348559014.

Watch Pascual Silva, JR. DBA Silva'S Painting AND Renovations LLC — free Get an email when a new federal OSHA severe-injury report for Pascual Silva, JR. DBA Silva'S Painting AND Renovations LLC is published. One employer, no account, unsubscribe in one click.
Site address
ALLEY BEHIND 4412 W. 44TH ST.
City
CHICAGO
State
IL
ZIP
60632
Mailing
804 JUNIE CT., JOLIET, IL 60435
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238320
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4965.00 · Current $4965.00
29 CFR  1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, or ungrounded electric power circuits that the employee could contact in the course of their work:  a.  On or about October 16, 2025, at the above addressed jobsite, an employee performing paint preparation activities from a JLG 460SJ Articulating Boom Lift was required to work within close proximity to energized electrical equipment, thereby exposing the employee to electrical hazards.
Recent events (1)
  • — Z (S) $4965

1926.416 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.416(a)(3): The employer began work without determining if employees could contact any part of an energized circuit and did not post warning signs and advise employees of the location of the circuit, hazards, and protective measures they need to take.  a.  On or about October 16, 2025, at the above addressed jobsite, the employer did not ensure that the performance of the work would not bring the employee and/or equipment into physical or electrical contact with any part of the energized electrical equipment, nor did the employer post warning signs and advise the employee of the hazards and protective measures to be taken, thereby exposing the employee to electrical hazards.
Recent events (1)
  • — Z (S) $0

1926.454 A

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  a.  On or about October 16, 2025, at the above addressed jobsite, the employer did not train each employee performing work from a JLG 460SJ Articulating Boom Lift and a JLG 660SJ Articulating Boom Lift on the hazards associated with using and operating an aerial lift, nor did the employer train employees on the nature of any electrical hazards in the work area and correct procedures for dealing with electrical hazards.
Recent events (1)