OSHA Inspection: BOSTON GAS

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of BOSTON GAS in BROAD STREET & SOUTHERN ARTERY, QUINCY, MA 02169 (NAICS 486210). OSHA activity number 348564642.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boston GAS for free Get an email when a new federal OSHA severe-injury report for Boston GAS is published. One employer, no account, unsubscribe in one click.
Establishment
BOSTON GAS
Site address
BROAD STREET & SOUTHERN ARTERY
City
QUINCY
State
MA
ZIP
02169
Mailing
170 DATA DRIVE, WALTHAM, MA 02451
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
486210
Employees
8
Ownership type
Private (A)

2 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 30, 2026
Penalty
Initial $16,550 · Current $8,275 Reduced
29 CFR  1926.416(a)(1):The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:   Location:  Electrical duct bank below the Southern Artery near the intersection with Broad Street  The employer allowed subcontractor employees to be exposed to up to 13.8 kV while jackhammering a 'live' electrical duct bank.
Recent events (2)
  • · I (S) $8275
  • · Z (S) $16550

1926.1153 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 30, 2026
Penalty
Initial $14,188 · Current $7,094 Reduced
29 CFR  1926.1153(c)(1):For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, nor did the  employer assess and limit the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.  Location:  Excavation near the intersection of Southern Artery and Broad Street  The employer allowed the dry chipping and jackhammering of a concrete duct bank and had not assessed silica exposures from this task.
Recent events (2)
  • · I (S) $7094
  • · Z (S) $14188

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348564642.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.