VALLEY CITY, OH —
OSHA Inspection: AUTOMATION TOOL & DIE INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AUTOMATION TOOL & DIE INC in 5576 INNOVATION DRIVE, VALLEY CITY, OH 44280 (NAICS 333515). OSHA activity number 348574765.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOMATION TOOL & DIE INC
- Site address
- 5576 INNOVATION DRIVE
- City
- VALLEY CITY
- State
- OH
- ZIP
- 44280
- Mailing
- 5576 INNOVATION DRIVE, VALLEY CITY, OH 44280
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333515
- Employees
- 73
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jan 28, 2026
- Penalty
- Initial $8,276 · Current $5,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about October 23, 2025, the employer's hazardous energy control procedure for 10 Station Servo Welder, Station 4, located in the welding department, did not include procedural steps for isolating the energy sources for employees performing maintenance and clearing jams of the upper and lower electrodes.
Recent events (2)
- — I (S) $5700
- — Z (S) $8276
1910.147 C04 II D
- Issued
- Jan 28, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures; On or about October 23, 2025 the employer failed to ensure that the energy control procedures for the 10 Station Servo Welder, Station 4 contained or outlined the procedures for testing and verifying the effectiveness of locking out the equipment prior to performing service or maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Automation Tool & DIE INC
View Automation Tool & DIE INC's full OSHA safety record →
More inspections in this industry (NAICS 333515)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348574765.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.