CORRY, PA —
OSHA Inspection: ASSOCIATED METAL FORMING TECHNOLOGIES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ASSOCIATED METAL FORMING TECHNOLOGIES in 226 S CENTER STREET, CORRY, PA 16407 (NAICS 336370). OSHA activity number 348597907.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASSOCIATED METAL FORMING TECHNOLOGIES
- Site address
- 226 S CENTER STREET
- City
- CORRY
- State
- PA
- ZIP
- 16407
- Mailing
- 226 S CENTER STREET, CORRY, PA 16407
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 140
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A03 II
- Issued
- Jan 20, 2026
- Penalty
- Initial $9,225 · Current $5,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycles: a.) Associated Metal Forming Technologies, dba Associated Spring Corry; 1900 Department - On or about 10/2/25, and at times prior thereto, the light curtain guarding set-up on the load cell tester was not designed to prevent the entry of hands into the machine's danger zone. The light curtains did not activate as soon as the equipment became active. An amputation occurred when an employee reached into the machine to change out cups and the hydraulic cylinder activated. NO ABATEMENT CERTIFICATION OR DOCUMENATION REQUIRED
Recent events (2)
- — I (S) $5700
- — Z (S) $9225
More inspections at Associated Metal Forming Technologies
View Associated Metal Forming Technologies's full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348597907.