PEDRICKTOWN, NJ —
OSHA Inspection: CMI - PROMEX, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CMI - PROMEX, INC. in 7 BENJAMIN GREEN ROAD, PEDRICKTOWN, NJ 08067 (NAICS 332999). OSHA activity number 348600693.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CMI - PROMEX, INC.
- Site address
- 7 BENJAMIN GREEN ROAD
- City
- PEDRICKTOWN
- State
- NJ
- ZIP
- 08067
- Mailing
- 7 BENJAMIN GREEN ROAD, PEDRICKTOWN, NJ 08067
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 17
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 L01 I
- Issued
- Feb 5, 2026
- Abate by
- Mar 4, 2026
- Penalty
- Initial $3,547 · Current $2,660 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Production Area and Yard: The employer did not provide forklift training to the employees driving forklifts including, but not limited to the Hyster Electric Forklift, Model E40XL-33, Serial Number C108V09120K on or about 11/19/25. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $2660.25
- — Z (S) $3547
1910.179 J03
- Issued
- Feb 5, 2026
- Abate by
- Mar 4, 2026
- Penalty
- Initial $3,547 · Current $2,660 Reduced
General-duty citation text
29 CFR 1910.179(j)(3):A complete periodic inspection of crane(s) had not been conducted in the past 12 months: (a)Production Area: Periodic inspections of the cranes used in the facility by employees, including, but not limited to the Load Lifter VI, Model 112139-1, Serial Number 30-91427, with a 2 ton capacity; the Strong Way G&L, Model 72642, Serial Number 220190872642087 with a 1 ton capacity; The Milwauke Saw, Model 9567, Serial Number JMB2197TU with a 1 ton capacity; and the DZ, Model OZ4000EC, Serial Number 0240000455 with a 2 ton capacity were not conducted on or about 11/19/25. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.
Recent events (2)
- — I (S) $2660.25
- — Z (S) $3547
1910.212 A01
- Issued
- Feb 5, 2026
- Abate by
- Mar 4, 2026
- Penalty
- Initial $3,547 · Current $2,660 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a)Production Area: Employees were exposed to rotating parts and flying metal chips in that the employer did not have a chuck guard in place, on the Reed Prentice Lathe, Serial Number 60643 operating at approximately 450 RPM on or about 11/19/25. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $2660.25
- — Z (S) $3547
1910.305 B01 II
- Issued
- Feb 5, 2026
- Abate by
- Mar 4, 2026
- Penalty
- Initial $2,128 · Current $1,596 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed: (a)Production Area near the Scotchman Ironworker: The 30 AMP, 3 Phase, 240 Volt electrical disconnect box serving the Scotchman Ironworker had an open knockout hole on or about 11/19/25. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $1596
- — Z (S) $2128
1910.147 C06 II
- Issued
- Feb 5, 2026
- Abate by
- Mar 4, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii):The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection (a) Production Area: Employees were exposed to hazardous energy, when the employer failed to ensure that periodic inspections of energy control procedures were properly documented. The employer did not identify the machine or equipment involved as required on or about 11/19/25 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.179 J02 IV
- Issued
- Feb 5, 2026
- Abate by
- Mar 4, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv):Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: a)Production Area: Monthly inspections with written certifications were not conducted on the chains used to hoist loads on cranes including, but not limited to the Load Lifter VI, Model 112139-1, Serial Number 30-91427, with a 2 ton capacity; the Strong Way G&L, Model 72642, Serial Number 220190872642087 with a 1 ton capacity; The Milwauke Saw, Model 9567, Serial Number JMB2197TU with a 1 ton capacity; and the DZ, Model OZ4000EC, Serial Number 0240000455 with a 2 ton capacity on or about 11/19/25. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CMI - Promex, INC.