STURTEVANT, WI —
OSHA Inspection: EJ EQUIPMENT
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EJ EQUIPMENT in 2626 NORTH SYLVANIA AVENUE, STURTEVANT, WI 53177 (NAICS 811111). OSHA activity number 348601782.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EJ EQUIPMENT
- Site address
- 2626 NORTH SYLVANIA AVENUE
- City
- STURTEVANT
- State
- WI
- ZIP
- 53177
- Mailing
- 6949 N 3000E ROAD, MANTENO, IL 60950
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 6
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.28 B01 I
- Issued
- Apr 17, 2026
- Abate by
- May 6, 2026
- Penalty
- Initial $11,585 · Current $6,900 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): (a) On or about November 19, 2025, the employer did not ensure that employees performing maintenance activities from the top of garbage trucks with an unprotected side, were protected from a fall hazard greater than four feet to the ground below.
Recent events (2)
- — I (S) $6900
- — Z (S) $11585
1910.147 C04 I
- Issued
- Apr 17, 2026
- Abate by
- Jun 15, 2026
- Penalty
- Initial $11,585 · Current $6,900 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about November 19, 2025, the employer failed to develop and implement hazardous energy control procedures to ensure employee safety during the servicing and maintenance of equipment at the facility, including, but not limited to, repairs on garbage trucks, thereby exposing employees to crushing and amputation hazards.
Recent events (2)
- — I (S) $6900
- — Z (S) $11585
1910.147 C07 I
- Issued
- Apr 17, 2026
- Abate by
- May 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) On or about November 19, 2025, the employer failed to develop and implement hazardous energy control training to ensure employee safety during the servicing and maintenance of equipment at the facility, including, but not limited to, repairs on garbage trucks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Apr 17, 2026
- Penalty
- Initial $6,620 · Current $3,900 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) On or about November 19, 2025, the employer did not ensure that employees were trained and certified to operate the forklift (Hyster 60, Model H60FT, Serial No.P177V10280S) at the facility. This exposed employees to struck-by and caught-in-between hazards.
Recent events (2)
- — I (S) $3900
- — Z (S) $6620
1910.178 Q07
- Issued
- Apr 17, 2026
- Abate by
- Apr 29, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) On or about November 19, 2025 the employer had not ensured that forklifts are examined at least daily prior to use, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01 I
- Issued
- Apr 17, 2026
- Abate by
- May 6, 2026
- Penalty
- Initial $9,931 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. (a) On or about November 19, 2025, employees were exposed to chemicals, such as, but not limited to Misty Red Grease Superfilm and Molysote while conducting production operations. The employer failed to develop and implement a written chemical inventory list that identified the potential hazards employees were exposed to while working with chemicals.
Recent events (2)
- — I (S) $4900
- — Z (S) $9931
1910.1200 H01
- Issued
- Apr 17, 2026
- Abate by
- May 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about November 19, 2025, the employer did not provided information and training on the hazards associated with the chemicals used as a part of daily job duties, including but is not limited to: Misty Red Grease Superfilm and Molysote.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B08 I
- Issued
- Apr 17, 2026
- Abate by
- Apr 29, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it is mounted. (a) On or about November 19, 2025, the company failed to correctly mount and secure an relocatable power strip onto a surface, exposing employees to a fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Apr 17, 2026
- Abate by
- Apr 29, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii):Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded. (a) On or about November 19, 2026, in the shop area, objects were stored within three feet of the electrical panel, creating a fire hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811111)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348601782.