PENSACOLA, FL —
OSHA Inspection: UNDERWOOD GROUP 1, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of UNDERWOOD GROUP 1, LLC in 3700 N. PALAFOX ST,, PENSACOLA, FL 32505 (NAICS 327991). OSHA activity number 348603598.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNDERWOOD GROUP 1, LLC
- Site address
- 3700 N. PALAFOX ST,
- City
- PENSACOLA
- State
- FL
- ZIP
- 32505
- Mailing
- 3700 N. PALAFOX ST,, PENSACOLA, FL 32505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 D02
- Issued
- Mar 2, 2026
- Abate by
- Mar 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: a) Fabrication shop: On or about November 19, 2025, the employer failed to verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated, the person certifying that the evaluation had been performed, the date(s) of the hazard assessment, and which identified the document as a certification of hazard assessment.
Recent events (1)
- — Z (O) $0
1910.134 E01
- Issued
- Mar 2, 2026
- Abate by
- Mar 16, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Fabrication Shop: On or about November 19, 2025, the employer failed to provide employees with medical evaluation to determine the employee's ability to use a respirator, before the employees were required to use the respirator in the workplace.
Recent events (1)
- — Z (O) $0
1910.134 F02
- Issued
- Mar 2, 2026
- Abate by
- Mar 16, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) Fabrication Shop: On or about November 19, 2025, the employer failed to provide employees using tight-fitting half facepiece respirators with fit testing prior to initial use of the respirators.
Recent events (1)
- — Z (O) $0
1910.134 G01 I A
- Issued
- Mar 2, 2026
- Abate by
- Mar 16, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A):Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) Fabrication shop: On or about November 19, 2025, the employer allowed employees with facial hair to wear half facepiece tight-fitting respirators, the facial hair came between the sealing surface of the facepiece and the face or interfered with the valve function of the respirator.
Recent events (1)
- — Z (O) $0
1910.134 H02 I
- Issued
- Mar 2, 2026
- Abate by
- Mar 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i):Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: a)Template designing area: On or about November 19, 2025, the employer failed to ensure that employees packed or stored their respirators in storage bags to prevent damage, contamination or deformation of the facepiece and exhalation valve.
Recent events (1)
- — Z (O) $0
1910.134 K06
- Issued
- Mar 2, 2026
- Abate by
- Mar 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6):The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) Fabrication shop: On or about November 19, 2025, the employer failed to provide employees who voluntarily wear N95 dust masks with basic advisory information on respirators as presented in Appendix D of 29 CFR 1910.134.