GALESVILLE, WI —
OSHA Inspection: NORWINN COMPANY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NORWINN COMPANY, INC. in 16949 NORTH 13TH STREET, GALESVILLE, WI 54630 (NAICS 337122). OSHA activity number 348607631.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORWINN COMPANY, INC.
- Site address
- 16949 NORTH 13TH STREET
- City
- GALESVILLE
- State
- WI
- ZIP
- 54630
- Mailing
- 16949 NORTH 13TH STREET, GALESVILLE, WI 54630
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337122
- Employees
- 35
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $11,585 · Current $8,110 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Shop floor; On or about November 19, 2025, and dates prior, the HOLZ-HER Edge Banding Machine (SN 191/1-708) lockout procedure was not used prior to performing servicing and maintenance activities such as but not limited to, cleaning edge banding material in the copy wheel and performing equipment troubleshooting. (b) Shop floor; On or about November 19, 2025, and dates prior, the Biesse Rover B 1650 CNC Machine (SN 1000009123) lockout procedure was not used prior to performing servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine. (c) Shop floor; On or about November 19, 2025, and dates prior, the Busellato CNC Machine lockout procedure was not used prior to performing servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine.
Recent events (2)
- — I (S) $8109.5
- — Z (S) $11585
1910.147 D03
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Shop floor; On or about November 19, 2025, and dates prior, the HOLZ-HER Edge Banding Machine (SN 191/1-708) was not isolated prior to performing servicing and maintenance activities such as but not limited to, cleaning edge banding material in the copy wheel and performing equipment troubleshooting. (b) Shop floor; On or about November 19, 2025, and dates prior, the Biesse Rover B 1650 CNC Machine (SN 1000009123) was not isolated prior to performing servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine. (c) Shop floor; On or about November 19, 2025, and dates prior, the Busellato CNC Machine was not isolated prior to performing servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Shop floor; On or about November 19, 2025, and dates prior, lockout or tagout device(s) were not affixed to the HOLZ-HER Edge Banding Machine (SN 191/1-708) prior to performing servicing and maintenance activities such as but not limited to, cleaning edge banding material in the copy wheel and performing equipment troubleshooting. (b) Shop floor; On or about November 19, 2025, and dates prior, lockout or tagout device(s) were not affixed to the Biesse Rover B 1650 CNC Machine (SN 1000009123) prior to performing servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine. (c) Shop floor; On or about November 19, 2025, and dates prior, lockout or tagout device(s) were not affixed to the Busellato CNC Machine prior to performing servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A02
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible and/or machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves: (a) Shop floor; On or about November 19, 2025, and dates prior, the HOLZ?HER Edge Banding Machine (SN 191/1?708) had two protective hoods (doors) with interlocks that were bypassed/defeated, exposing employees to the hazardous moving parts inside the enclosure. The interlock tongue/key for each door had been unbolted from the doors and placed in the interlock holders, allowing the machine to operate with the hood doors open. (b) Shop floor; On or about November 19, 2025, and dates prior, the Biesse Rover B 1650 CNC Machine (SN 1000009123) had an unguarded gap on the front left side of the perimeter fence that allowed employees to enter the rear of the machine without passing through the interlocked gate. This opening permitted direct access to hazardous moving parts, including the beam/trolley/carriage's traversing motion, while bypassing the intended safeguarding function of the interlocked enclosure. (c) Shop floor; On or about November 19, 2025, and dates prior, the Busellato CNC Machine had two perimeter?fence sections removed, creating an 18?inch?wide gap at the front left side and a second gap approximately 4 feet wide at the front right side, that allowed employees to enter the rear of the machine without passing through the interlocked gate. Both openings permitted direct access to hazardous moving parts, including the beam/trolley/carriage's traversing motion, while bypassing the intended safeguarding function of the interlocked enclosure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I C
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $7,035 · Current $4,925 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout is used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: (a) Shop floor; On or about November 19, 2025, and dates prior, the periodic inspection did not include a review between the inspector, the authorized employee(s), and the energy control procedures for equipment including but not limited to the HOLZ-HER Edge Banding Machine (SN 191/1-708), the Biesse Rover B 1650 CNC Machine (SN 1000009123), and the Busellato CNC Machine.
Recent events (2)
- — I (S) $4924.5
- — Z (S) $7035
1910.147 C06 II
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) Shop floor; On or about November 19, 2025, and dates prior, a record/certification of completion was not maintained to document that energy control (lockout/tagout) procedures were evaluated for equipment including but not limited to the HOLZ-HER Edge Banding Machine (SN 191/1-708), the Biesse Rover B 1650 CNC Machine (SN 1000009123), and the Busellato CNC Machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) Shop floor; On or about November 19, 2025, and dates prior, the employer did not provide authorized-level training to employees working on the HOLZ-HER Edge Banding Machine (SN 191/1-708), including servicing and maintenance activities such as but not limited to, cleaning edge banding material in the copy wheel and performing equipment troubleshooting. (b) Shop floor; On or about November 19, 2025, and dates prior, the employer did not provide authorized-level training to employees working on the Biesse Rover B 1650 CNC Machine (SN 1000009123), including servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine. (c) Shop floor; On or about November 19, 2025, and dates prior, the employer did not provide authorized-level training to employees working on the Busellato CNC Machine, including servicing and maintenance activities such as but not limited to, changing bits/tooling and cleaning within the perimeter fenced area behind the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Mar 12, 2026
- Abate by
- Mar 26, 2026
- Penalty
- Initial $4,220 · Current $2,954 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Shop floor; On or about November 19, 2025, and dates prior, compressed air blow guns used for cleaning equipment, including but not limited to the HOLZ-HER Edge Banding Machine (SN 191/1-708), the Biesse Rover B 1650 CNC Machine (SN 1000009123), and the Busellato CNC Machine, were operated with an expelled pressure exceeding 30 p.s.i.
Recent events (2)
- — I (S) $2954
- — Z (S) $4220
More inspections at Norwinn Company, INC.
View Norwinn Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337122)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348607631.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.