PHILIPSBURG, PA —
OSHA Inspection: PMG PENNSYLVANIA CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PMG PENNSYLVANIA CORPORATION in 187 ENTERPRISE DRIVE, PHILIPSBURG, PA 16866 (NAICS 332117). OSHA activity number 348609314.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PMG PENNSYLVANIA CORPORATION
- Site address
- 187 ENTERPRISE DRIVE
- City
- PHILIPSBURG
- State
- PA
- ZIP
- 16866
- Mailing
- 187 ENTERPRISE DRIVE C/O MORGAN GARDNER, PHILIPSBURG, PA 16866
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332117
- Employees
- 124
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 A01
- Issued
- Feb 20, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $7,235 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): Places of employment were not kept clean: (a) PMG Pennsylvania Corporation, 187 Enterprise Drive, Philipsburg, Pennsylvania - Combustible powdered metal dust had accumulated on ceiling level surfaces, including ductwork, exposing employees to a fire hazard, on or about November 20, 2025. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $7000
- — Z (S) $7235
1910.147 C06 I
- Issued
- Feb 20, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $7,235 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) PMG Pennsylvania Corporation, 187 Enterprise Drive, Philipsburg, Pennsylvania - The employer did not conduct an annual periodic inspection of lockout/tagout procedures, exposing employees to machinery hazards such as caught in, entanglement, and struck by, on or about November 20, 2025. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $7235
1910.219 C04 I
- Issued
- Feb 20, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $5,426 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft ends did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) Furnace 4 - The horizontal shaft end, 41 inches above the floor, on the belt conveyor where the belt dumps excess powder off parts before Furnace 4, did not present a smooth edge due to having set screws, and this shaft end did not have guarding, on or about November 20, 2025. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $5000
- — Z (S) $5426
1910.303 B02
- Issued
- Feb 20, 2026
- Abate by
- May 1, 2026
- Penalty
- Initial $5,426 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Presto Power Stak Lift Parking Area - A two-receptacle metal knockout box, installed as a pendant on a flexible cord, supplied power to cord and plug connected equipment, including the charging cord for the Presto Power Stak Lift. This use did not follow the listing, labeling, and certification for receptacles, which require using non-metallic enclosures and cover plates for pendent receptacles, on or about November 20, 2025. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $5000
- — Z (S) $5426
More inspections at PMG Pennsylvania Corporation