Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HIGHCROSS HEALTHCARE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HIGHCROSS HEALTHCARE, INC. in 14699 EAST HAMPDEN AVE, AURORA, CO 80014 (NAICS 623110). OSHA activity number 348610809.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Highcross Healthcare, INC. — free Get an email when a new federal OSHA severe-injury report for Highcross Healthcare, INC. is published. One employer, no account, unsubscribe in one click.
Site address
14699 EAST HAMPDEN AVE
City
AURORA
State
CO
ZIP
80014
Mailing
14699 EAST HAMPDEN AVENUE, AURORA, CO 80014
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
253
Ownership type
A

3 citations on file for this inspection.

1910.332 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 13, 2026
Abate by
Apr 17, 2026
Penalty
Initial $16,550 · Current $11,000 Reduced
29 CFR  1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety:    a) On or before November 19, 2025, the employer did not ensure that employees who worked near potential electrical hazards were provided with training on electrically related safety practices. The employer allowed an unqualified employee to be exposed to electrical shock hazards as they were not trained and familiar with electrically related safety practices, prior to using a  Niuyhe 5-24 Foot Aluminum Telescopic Extension Pole to hang holiday lights on a tree while working from the ground within the minimum approach distance of uninsulated primary conductors that were energized with 7.2kV.  This exposed employees to electric shock hazards.
Recent events (2)
  • — I (S) $11000
  • — Z (S) $16550

1910.333 C03 I B

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 13, 2026
Abate by
Apr 17, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.333(c)(3)(i)(B): When an unqualified person is working on the ground in the vicinity of overhead lines, the person may not bring any conductive object closer to unguarded, energized overhead lines than the distances given in 29 CFR 1910.333(c)(3)(i)(A).  a) On or before November 19, 2025, the employer allowed an unqualified employee to be exposed to electrical shock hazards while using a conductive Niuyhe 5-24 Foot Aluminum Telescopic Extension Pole to install holiday lights on a tree that was adjacent to the uninsulated primary conductors that were energized to 7.2 kV. The employee made direct contact with the lowest power line with the pole which resulted in an electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 13, 2026
Abate by
Apr 17, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  a) On or before November 19, 2025, the employer allowed an unqualified employee to be exposed to electrical shock hazards by using a conductive Niuyhe 5-24 Foot Aluminum Telescopic Extension Pole to hang holiday lights on an outdoor tree by primary uninsulated conductors that were energized with 7.2kV without any electrical protective equipment. The employee made direct contact with the lowest power line with the aluminum telescopic extension pole which resulted in an electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348610809.