CALHAN, CO —
OSHA Inspection: TAPIA ROOFING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TAPIA ROOFING LLC in 470 GALVESTON TERRACE, CALHAN, CO 80808 (NAICS 238160). OSHA activity number 348615360.
Where did this inspection happen?
- Establishment
- TAPIA ROOFING LLC
- Site address
- 470 GALVESTON TERRACE
- City
- CALHAN
- State
- CO
- ZIP
- 80808
- Mailing
- 4825 ASTROZON BLVD. LOT B-225, COLORADO SPRINGS, CO 80916
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3972.00 · Current $3972.00
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a) On or about November 25, 2025, and at times prior, the employer did not ensure that employees engaged in residential roofing activities more then 6ft above the lower level were protected from fall hazards by guardrail systems, safety net system, or personal fall arrest system.
Recent events (1)
- — Z (S) $3972
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3405.00 · Current $3405.00
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On or about November 25, 2025, and at times prior, the employer did not ensure that portable ladders used for access to the residential roof were extended at least 3 feet above the upper landing surface being accessed.
Recent events (1)
- — Z (S) $3405
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348615360.