Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: KINTON CARBIDE, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of KINTON CARBIDE, INC. in 3000 VENTURE COURT WESTMORELAND INDUSTRIAL PARK #3, EXPORT, PA 15632 (NAICS 332313). OSHA activity number 348623778.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kinton Carbide, INC. for free Get an email when a new federal OSHA severe-injury report for Kinton Carbide, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3000 VENTURE COURT WESTMORELAND INDUSTRIAL PARK #3
City
EXPORT
State
PA
ZIP
15632
Mailing
3000 VENTURE COURT WESTMORELAND INDUSTRIAL PARK #3, EXPORT, PA 15632
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
332313
Employees
12
Ownership type
Private (A)

2 citations on file for this inspection.

1910.95 C01

Repeat Gravity 5 2 instances 4 exposed
Issued
Jan 27, 2026
Penalty
Initial $17,735 · Current $10,500 Reduced

Hazardous substances 8111

29 CFR  1910.95(c)(1):  The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  a)  In the Facility, on or about December 10, 2025 - The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA.  An employee designated as a Brazer was exposed to noise at a level of 93.3% of the allowable limit during a 264 minute sampling period on December 10, 2025.  This exposure is equivalent to a sound level of 89.5 dBA for the dose and time of employee exposure and is 1.86 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.  b) In the Facility, on or about December 10, 2025 -  An employee designated as a Brazer was exposed to noise at a level of 71.7% of the allowable limit during a 264 minute sampling period on December 10, 2025 .  This exposure is equivalent to a sound level of 87.6 dBA for the dose and time of employee exposure and is 1.43 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.  Kinton Carbide, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.95(c)(1), which was contained in OSHA inspection number 1674655, citation number 1, item number 1a, and was affirmed as a final order on July 24, 2023 with respect to a workplace located at 3000 Venture Court, Export, PA 15632.
Recent events (2)
  • · I (R) $10500
  • · Z (R) $17735

1910.95 G01

Repeat Gravity 5 2 instances 4 exposed
Issued
Jan 27, 2026
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR  1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:  a)  In the Facility, on or about December 10, 2025 - The employer did not maintain an audiometric testing program for all employees whose noise exposures equaled or exceeded an 8-hour time-weighted average noise exposure of 85 decibels.  Employees of the facility did not receive an annual audiometric test after being provided one on July 10, 2024.  An employee designated as a Brazer was exposed to noise at a level of 93.3% of the allowable limit during a 264 minute sampling period on December 10, 2025.  This exposure is equivalent to a sound level of 89.5 dBA for the dose and time of employee exposure and is 1.86 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.  b) In the Facility, on or about December 10, 2025 - The employer did not maintain an audiometric testing program for all employees whose noise exposures equaled or exceeded an 8-hour time-weighted average noise exposure of 85 decibels.  Employees of the facility did not receive an annual audiometric test after being provided one on July 10, 2024.   An employee designated as a Brazer was exposed to noise at a level of 71.7% of the allowable limit during a 264 minute sampling period on December 10, 2025 .  This exposure is equivalent to a sound level of 87.6 dBA for the dose and time of employee exposure and is 1.43 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.  Kinton Carbide, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.95(g)(1), which was contained in OSHA inspection number 1674655, citation number 1, item number 1b, and was affirmed as a final order on July 24, 2023 with respect to a workplace located at 3000 Venture Court, Export, PA 15632.
Recent events (2)
  • · I (R) $0
  • · Z (R) $0